CPET Basic Results Last Name ID Age Sex Opina, Martin 23 male Weight Height 65.0 kg 171 cm Date Duration Operator 5/10/2019 11:07 AM 0:14:57 Bernaciková, Martina Workload Protocol Device Workload Device MetaLyzer 3B-R3 Lode Excalibur 38k4 Ambient Conditions Temperature Pressure 24.5°C 977mBar Summary Table Variable Unit Rest VT1 VT2 V'02peak Value % Norm % Max Value % Norm % Max Value % Norm Norm. V'02/kg V02/HR HR WR V'E/V'02 VE/VC02 RER V'E VT BF ml/min/kg ml /min W L/min L /min 6.24 6.31 65 0 28.10 29.12 0.97 13.22 1.03 13 37.25 17.61 138 198 22.17 22.44 0.99 56.86 2.38 24 82 106 78 75 48 58 63 82 77 60 68 80 86 44 81 54 52.50 20.43 167 279 25.99 24.55 1.06 93.28 2.75 34 116 123 94 106 79 82 89 95 93 84 80 87 92 59.11 21.49 179 331 32.44 28.15 1.15 71 130.56 93 2.96 77 44 131 45.21 129 16.60 101 177 125 264 111 117.48 107 41 Lipid Metabolism Absolute Maximum Values Variable Unit Maximum lipid metabolism = 30-32g/h at Heart Rate Range = 109-110/min Medical Findings Value HR /min 109-110 WR W 88-90 FAT g/h 30-32 CHO g/h 16-29 EE kcal/h 392-436 Variable V'02/kg V02/HR HR WR V'E/V'02 VE/VC02 RER V'E VT BF Unit ml/min/kg ml /min W L/min L /min Value 61.56 23.43 183 342 37.59 31.65 1.20 152.80 3.21 57 The patient performed a maximum exercise test to 331W and reached a V'02peak of 3.842L/min. This is above the normal value 2.939L/min (131%). The relative maximum oxygen uptake (V'02/kg) is 59.11 ml/min/kg. Based on Classification by AHA the fitness level is assessed as Excellent. At maximum exercise the respiratory exchange ratio (RER) was 1.15 and the heart rate (HR) was 179/min, what is 101% of the normal value. The test was aborted by reasons of Loss of performance. The VT1 is 2.421 L/min or 37.25ml/min/kg. This is 82% of the normal maximum oxygen uptake or 63% of the reached maximum oxygen uptake. Ambulance tělovýchovného lékařství Created on: 5/10/2019 11:25 AM Univerzitní Kampus MU, Brno Internet: http://www.lhrazdira.eu/telovychovnelekarstvi CPET Basic Results Patient Opina, Martin Date 5/10/2019 11:07 AM Normal Values - | Variable Maximum Oxygen Uptake Maximum Heart Rate Maximum Oxygen Pulse Maximum Work Rate Maximum Minute Ventilation Maximum Breathing Frequency Reasons for Test Abort Loss of performance [Author Wasserman weight algorithm Traditional formula for bicycle test Wasserman equation Based on normal maximum oxygen uptake Individual normal value, based on MVV or FEV1 Pollock et al. equation Value Unit 2.939 L/min 177 /min 16.60 ml 264 W 117.48 L/min 41 /min Ambulance tělovýchovného lékařství Created on: 5/10/2019 11:25 AM Univerzitní Kampus MU, Brno Internet: http://www.lhrazdira.eu/telovychovnelekarstvi CPET Basic Results Patient Opina, Martin Date 5/10/2019 11:07 AM Ventilatory Threshold 1 - VTl: 2.421L/min 82% of predicted V'02max 63% of reached V'02peak VT1 is determined based on smoothed data by Moving data points average method 3. The calculation range was 0:01:58-0:11:48. r i r - -> ť _....... > / / / ✓ / / / / / / / / / L J \ -----& A. >* / r," , > / t-/__________ */ :+/ A* / / / ' / / s / - -,f,r ->'/ / / 0 !-1-1-1-!-1---1 0 1 2 3 4 5 V'02 [L/min] Ambulance tělovýchovného lékařství Created on: 5/10/2019 11:25 AM Univerzitní Kampus MU, Brno Internet: http://www.lhrazdira.eu/telovychovnelekarstvi CPET Basic Results Patient Opina, Martin Date 5/10/2019 11:07 AM Ventilatory Threshold 1 (continuation) o > Time Ol X 5(?0:00 X O U Time o u Time Ambulance tělovýchovného lékařství Created on: 5/10/2019 11:25 AM Univerzitní Kampus MU, Brno Internet: http://www.lhrazdira.eu/telovychovnelekarstvi CPET Basic Results Patient Opina, Martin Date 5/10/2019 11:07 AM Ventilatory Threshold 2 - VT2: 3.413L/min 116% of predicted V'02max 89% of reached V'02peak VT2 is determined based on smoothed data by Moving data points average method 3. The calculation range was 0:07:55-0:14:53. 60 - ----iflr"- I -I - I I I 2 3 VC02 [L/min] at* - o > r V 20.00 Q Time 100 L IN g 6o°o Time Ambulance tělovýchovného lékařství Created on: 5/10/2019 11:25 AM Univerzitní Kampus MU, Brno Internet: http://www.lhrazdira.eu/telovychovnelekarstvi CPET Basic Results Patient Opina, Martin Date 5/10/2019 11:07 AM Maximum Oxygen Uptake - V'02peak: 3.842L/min 131% of predicted V'02max V'02peak is determined based on smoothed data by Moving data points average method 3. 5 !-!-!-!-!-Mfl-1 §0:00 03:00 06:00 09:00 12:00 15:00 Time Ambulance tělovýchovného lékařství Created on: 5/10/2019 11:25 AM Univerzitní Kampus MU, Brno Internet: http://www.lhrazdira.eu/telovychovnelekarstvi CPET Basic Results Patient Opina, Martin Date 5/10/2019 11:07 AM Lipid Metabolism - Maximum lipid metabolism = 30-32g/h at Heart Rate Range = 109-110/min Lipid Metabolism is determined based on smoothed data by Moving data points average method 3. ^ 600 L 1000 L 200 L 0 1 u E Time Ambulance tělovýchovného lékařství Created on: 5/10/2019 11:25 AM Univerzitní Kampus MU, Brno Internet: http://www.lhrazdira.eu/telovychovnelekarstvi