Laser ablation Methods for Analysis of Urinary Stones: Comparison Study Based on Calibration Pellets
NOVOTNÝ, Karel, Kateřina ŠTĚPÁNKOVÁ, Michaela VAŠINOVÁ GALIOVÁ, Viktor KANICKÝ, Jozef KAISER and David HAHN. Laser ablation Methods for Analysis of Urinary Stones: Comparison Study Based on Calibration Pellets. In SCIX 2012. 2012. |
Other formats:
BibTeX
LaTeX
RIS
|
Basic information | |
---|---|
Original name | Laser ablation Methods for Analysis of Urinary Stones: Comparison Study Based on Calibration Pellets |
Name in Czech | Metody laserové ablace pro analýzu močových kamenů: srovnávací studie založená na kalibračních tabletách |
Authors | NOVOTNÝ, Karel (203 Czech Republic, guarantor, belonging to the institution), Kateřina ŠTĚPÁNKOVÁ (203 Czech Republic, belonging to the institution), Michaela VAŠINOVÁ GALIOVÁ (203 Czech Republic, belonging to the institution), Viktor KANICKÝ (203 Czech Republic, belonging to the institution), Jozef KAISER (203 Czech Republic) and David HAHN (840 United States of America). |
Edition | SCIX 2012, 2012. |
Other information | |
---|---|
Original language | English |
Type of outcome | Conference abstract |
Field of Study | 10406 Analytical chemistry |
Country of publisher | United States of America |
Confidentiality degree | is not subject to a state or trade secret |
RIV identification code | RIV/00216224:14740/12:00061405 |
Organization unit | Central European Institute of Technology |
Keywords (in Czech) | LIBS; Laserová ablace; močové kameny; kalibrační tablety |
Keywords in English | LIBS; Laser ablation; urinary stones; calibration pellets |
Tags | International impact |
Changed by | Changed by: doc. Mgr. Karel Novotný, Ph.D., učo 17748. Changed: 29/3/2013 08:54. |
Abstract |
---|
Methods based on laser ablation, such as Laser Induced Breakdown Spectroscopy (LIBS) and Laser Ablation Inductively Coupled Plasma Mass/Optical Emission Spectrometry (LA-ICP-MS/OES) are particularly suitable for urinary stones bulk and micro analysis. The aim of this study is to demonstrate the calibration capabilities and limitations of these techniques. There are no commercially available standards, which would correspond to urinary calculi matrix. Internal standardization is also difficult, mainly due to different crystalline phases in one kidney stone. Calibration pellets were prepared from human urinary stones with phosphate, oxalate and urate matrix. For this comparative study the most frequently used laser-ablation based analytical techniques were chosen, such as LIBS and LA-ICP-MS. Moreover some unconventional techniques such as simultaneous LIBS – LA-ICP-OES and laser ablation (LA) – LIBS were also utilized. |
Abstract (in Czech) |
---|
Metody založené na laserové ablaci, jako spektroskopie laserem buzeného plazmatu (LIBS) a Laserová ablace ve spojení s hmotnostní nebo optickou spektrometrií indukčně vázaného plazmatu (LA-ICP-MS/OES) jsou velice vhodné pro mikroanalýzu a stanovení průměrného složení močových kamenů. Úkolem této studie je demonstrovat možnosti a omezení správné kalibrace těchto technik. Standardy obsahující tento typ matrice nejsou komerčně dostupné a použití porovnávacího prvku je ztíženo díky rozmanité krystalové struktuře močových kamenů. Kalibrační tablety proto byly připraveny z reálných močových kamenů s různou matricí - fosfátovou, oxalátovou a urátovou. Pro tuto srovnávací studii byly zvoleny jednak běžné metody laserové ablace jako je LIBS a LA-ICP-MS technika, a dále poněkud netradiční přístupy jako je simultánní LIBS a LA-ICP-OES měření a technika kombinující laserovou ablaci a spektrometrii laserem buzeného plazmatu (LA-LIBS). |
Links | |
---|---|
ED1.1.00/02.0068, research and development project | Name: CEITEC - central european institute of technology |
ME08002, research and development project | Name: Použití spektroskopie laserem buzeného plazmatu (LIBS) a laserové ablace ve spojení s ICP-OES/MS spektroskopií pro chemické mapování biominerálů |
Investor: Ministry of Education, Youth and Sports of the CR, Utilization of the laser induced breakdown spectroscopy (LIBS) and laser ablation ICP-OES/MS spectroscopy for chemical mapping of biominerals, Research and Development Programme KONTAKT (ME) |
PrintDisplayed: 29/9/2024 18:26