Detailed Information on Publication Record
2012
Simultaneous System of DP-LIBS and Laser Ablation ICP-OES
NOVOTNÝ, Karel, Aleš HRDLIČKA, Kateřina ŠTĚPÁNKOVÁ, Viktor KANICKÝ, Jozef KAISER et. al.Basic information
Original name
Simultaneous System of DP-LIBS and Laser Ablation ICP-OES
Name in Czech
Simultánní systém DP-LIBS a Laserová ablace ve spojení s ICP-OES
Authors
NOVOTNÝ, Karel (203 Czech Republic, guarantor, belonging to the institution), Aleš HRDLIČKA (203 Czech Republic, belonging to the institution), Kateřina ŠTĚPÁNKOVÁ (203 Czech Republic, belonging to the institution), Viktor KANICKÝ (203 Czech Republic, belonging to the institution), Jozef KAISER (203 Czech Republic), Radomír MALINA (203 Czech Republic) and David HAHN (840 United States of America)
Edition
ESAS 2012, 2012
Other information
Language
English
Type of outcome
Konferenční abstrakt
Field of Study
10406 Analytical chemistry
Country of publisher
Slovakia
Confidentiality degree
není předmětem státního či obchodního tajemství
References:
RIV identification code
RIV/00216224:14740/12:00061416
Organization unit
Central European Institute of Technology
ISBN
978-80-223-3292-7
Keywords (in Czech)
LIBS; Laserová ablace; ICP-OES
Keywords in English
LIBS; Laser ablation; ICP-OES
Tags
International impact
Změněno: 29/3/2013 08:55, doc. Mgr. Karel Novotný, Ph.D.
V originále
The simultaneous DP-LIBS and Laser-Ablation ICP-OES setup was designed by utilizing a modified commercially available laser ablation system UP-266 Macro (New Wave). Specially designed ablation chamber was developed to allow combination LIBS, DP-LIBS and LA-ICP-OES technique. In preliminary results washout efficiency of new ablation chamber was verified. Basic signal comparison of DP-LIBS and double pulse LA-ICP-OES were studied on the urinary stone cross-section. Results demonstrate high sensitivity for both methods and high spatial resolution.
In Czech
Simultánní systém DP-LIBS a Laserové ablace ve spojení s ICP-OES spektrometrií byl navržen s využitím modifikovaného komerčního systému UP-266 Macro (New Wave). Speciálně vyvinutá ablační komora byla konstruována pro možnost kombinace technik LIBS, DP-LIBS a LA-ICP-OES spektrometrie. V předběžných experimentech byla ověřena vysoká efektivita průplachu komory. Základní porovnání signálů DP-LIBS a LA-ICP-OES technik bylo provedeno na řezu močového kamene. Výsledky ukazují vysokou citlivost obou metod a vysoké prostorové rozlišení.
Links
ED1.1.00/02.0068, research and development project |
| ||
ME08002, research and development project |
|