Detailed Information on Publication Record
2012
Simultaneous determination of metal traces using SPE preconcentration on Amberlite XAD-7 by ICP-MS in environmental water and sample ecotoxicology assessment.
HOLUBOVA, Z., L. SOMMER, M. MOOS and Jan KUTABasic information
Original name
Simultaneous determination of metal traces using SPE preconcentration on Amberlite XAD-7 by ICP-MS in environmental water and sample ecotoxicology assessment.
Authors
HOLUBOVA, Z. (203 Czech Republic, guarantor), L. SOMMER (203 Czech Republic), M. MOOS (203 Czech Republic) and Jan KUTA (203 Czech Republic, belonging to the institution)
Edition
Fresenius Environmental Bulletin, FREISING, Germany, PARLAR SCIENTIFIC PUBLICATIONS (P S P), 2012, 1018-4619
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10511 Environmental sciences
Country of publisher
Germany
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 0.641
RIV identification code
RIV/00216224:14310/12:00063907
Organization unit
Faculty of Science
UT WoS
000312412700018
Keywords in English
Solid Phase Extraction; Amberlite XAD-7; ICP-MS and Waters; Ecotoxicology
Změněno: 11/4/2013 17:27, Ing. Andrea Mikešková
Abstract
V originále
This study has been focused on the determination of nine trace elements Be-9, V-51, Co-59, Ni-60, Y-89, led, (208)pb, Th-232 and U-238 by inductively coupled plasma mass spectrometry (ICP-MS) in natural waters and water samples after mining and processing of uranium.An ICP-MS spectrometer Agilent 7500ce, with a plasma generator of 27.12 MHz, power output of 1500 W and concentric nebulizer MicroMist (TM) with a cooled Scott chamber was used. The nonspectral interferences were eliminated by using a solution of internal standards Li-6 for Be-9, Sc-45 (V-51), Ge-72 (Co-59, Ni-60, (89)y), Rh-103 (Cd-111), Bi-209 ((208)pb, Th-232, U-238) The spectral interferences were eliminated by using the Helium collision cell during measurement. Monitored interfering elements were K+, Na+, NH4+ Ca2+, Mg2+, Al3+, Fe3+ and Cl-, HCO3-, SO42-, PO43-. For the preconcentration polymeric sorbent Amberlite XAD-7 was used. Elements were retained as their chelates with different organic reagents: 4-(2-pyridylazo) resorcinol (PAR), 3,4-Dihydroxy-9,10-dioxo-2-anthracenesulfonic acid sodium salt (ALS), 8-Hydroxyquinoline-5-sulphonic acid (8HQS) and Ammonium pyrrolidinedithiocarbamate (APDC).The sorption process was studied under various conditions with respect to pH. Sorbents were also conditioned with different surfactants: Benzyldimethyltetradecylammonium chloride (Zephyramine), 1-etoxycarbonyl-pentadecyl-trimethyl-ammonium bromide (Septonex (R)), Brij 35 or Sodium Dodecylsulphate (SDS). Various elution mixtures were also tested, the best results were obtained for the mixture of acetone and ethanol (1:1) in the presence of 1 mol.l(-1) HCl. The excess of acid and organic solvents were evaporated in Teflon (R) dishes prior to the determination by ICP-MS. The Thamnocephalus platyurus as THAMNOTOXKIT F (TM), Daphnia magna as a DAPHTOXKIT F (TM) and Artemia sauna as Artoxkit M (TM) are organisms, which were used for ecotoxicology assessment of water samples after mining of uranium.
Links
ED0001/01/01, research and development project |
|