ZITKA, Ondrej, Natalia CERNEI, Zbynek HEGER, Miroslav MATOUSEK, Pavel KOPEL, Jindrich KYNICKY, Michal MASAŘÍK, Rene KIZEK a Vojtech ADAM. Microfluidic chip coupled with modified paramagnetic particles for sarcosine isolation in urine. Electrophoresis. Hoboken: Wiley-Blackwell, 2013, roč. 34, č. 18, s. 2639-2647. ISSN 0173-0835. Dostupné z: https://dx.doi.org/10.1002/elps.201300114.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Microfluidic chip coupled with modified paramagnetic particles for sarcosine isolation in urine
Autoři ZITKA, Ondrej (203 Česká republika), Natalia CERNEI (203 Česká republika), Zbynek HEGER (203 Česká republika), Miroslav MATOUSEK (203 Česká republika), Pavel KOPEL (203 Česká republika), Jindrich KYNICKY (203 Česká republika), Michal MASAŘÍK (203 Česká republika, garant, domácí), Rene KIZEK (203 Česká republika) a Vojtech ADAM (203 Česká republika).
Vydání Electrophoresis, Hoboken, Wiley-Blackwell, 2013, 0173-0835.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10600 1.6 Biological sciences
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 3.161
Kód RIV RIV/00216224:14110/13:00070631
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1002/elps.201300114
UT WoS 000327590900006
Klíčová slova anglicky Ion exchange chromatography; Magnetic nanoparticles; Microfluidic separation; Prostate cancer; Surface modification
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Mgr. Věra Pospíšilíková, učo 9005. Změněno: 13. 4. 2014 12:34.
Anotace
Carcinoma of prostate (CaP) is the second most frequent malignant tumor occurring in men in Europe. Currently there is discussion on a wide range of potential CaP markers. One of them-nonprotein amino acid sarcosine, also known as N-methylglycine was chosen as a challenge for the development of microfluidic system with isolation by modified paramagnetic microparticles. Therefore, the aim of this study was to design a low-cost, simple, and rapid microfluidic system based on sarcosine isolation with modified paramagnetic microparticles and subsequent analysis on the ion exchange LC. We modified Dowex microparticles with Fe2O3 nanoparticles. Our paramagnetic microparticles were able to establish the binding with sarcosine. Moreover, we designed microfluidic device for sarcosine determination. Analysis of samples was carried out with LOD of 1 uM of a sarcosine that is sufficient because it is similar to concentrations of a sarcosine observed in the CaP patients.
VytisknoutZobrazeno: 1. 9. 2024 01:16