KORMUNDA, Martin, Tomáš HOMOLA, Jindrich MATOUSEK, Dušan KOVÁČIK, Mirko ČERNÁK a Jaroslav PAVLIK. Surface analysis of poly(ethylene naphthalate) (PEN) films treated at atmospheric pressure using diffuse coplanar surface barrier discharge in air and in nitrogen. Polymer Degradation and Stability. 2012, roč. 97, č. 4, s. 547-553. ISSN 0141-3910. Dostupné z: https://dx.doi.org/10.1016/j.polymdegradstab.2012.01.014.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Surface analysis of poly(ethylene naphthalate) (PEN) films treated at atmospheric pressure using diffuse coplanar surface barrier discharge in air and in nitrogen
Autoři KORMUNDA, Martin (203 Česká republika), Tomáš HOMOLA (703 Slovensko, garant), Jindrich MATOUSEK (203 Česká republika), Dušan KOVÁČIK (703 Slovensko), Mirko ČERNÁK (703 Slovensko, domácí) a Jaroslav PAVLIK (203 Česká republika).
Vydání Polymer Degradation and Stability, 2012, 0141-3910.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10305 Fluids and plasma physics
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.770
Kód RIV RIV/00216224:14310/12:00070892
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.polymdegradstab.2012.01.014
UT WoS 000301911300010
Klíčová slova anglicky ESCA/XPS;poly(ethylene naphthalate) (PEN);Coplanar surface barrier discharge;atmospheric plasma;surface modification
Štítky AKR, rivok
Změnil Změnil: doc. RNDr. Tomáš Homola, PhD., učo 119468. Změněno: 27. 2. 2018 14:45.
Anotace
Surface modi!cation of poly(ethylene naphthalate) (PEN) !lms by Diffuse Coplanar Surface Barrier Discharge (DCSBD) in ambient air and nitrogen at atmospheric pressure was studied at short plasma exposure times from 1 s up to 10 s. Chemical changes in the surface composition after the plasma treatments were studied using a high resolution XPS (X-ray Photoelectron Spectroscopy). The water contact angle was reduced from an initial value of 79! to values of 31! and 20! for the ambient air and nitrogen plasma treatments. After 3 days of storage in ambient air the contact angles were still about 50! and 40!, respectively. The polar component of surface energy was changed by the aging signi!cantly less than the total surface energy. Despite the marked increase in the surface energy, the plasma treatment had no signi!cant in"uence on the surface morphology.
VytisknoutZobrazeno: 1. 9. 2024 00:56