TOMALOVÁ, Iva, Pavla FOLTYNOVÁ, Viktor KANICKÝ and Jan PREISLER. MALDI MS and ICP MS Detection of a Single CE Separation Record: A Tool for Metalloproteomics. Analytical Chemistry. Washington: American Chemical Society, vol. 86, No 1, p. 647-654. ISSN 0003-2700. doi:10.1021/ac402941e. 2014.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name MALDI MS and ICP MS Detection of a Single CE Separation Record: A Tool for Metalloproteomics
Authors TOMALOVÁ, Iva (203 Czech Republic, belonging to the institution), Pavla FOLTYNOVÁ (203 Czech Republic, belonging to the institution), Viktor KANICKÝ (203 Czech Republic, belonging to the institution) and Jan PREISLER (203 Czech Republic, guarantor, belonging to the institution).
Edition Analytical Chemistry, Washington, American Chemical Society, 2014, 0003-2700.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10406 Analytical chemistry
Country of publisher United States of America
Confidentiality degree is not subject to a state or trade secret
WWW URL
Impact factor Impact factor: 5.636
RIV identification code RIV/00216224:14740/14:00073485
Organization unit Central European Institute of Technology
Doi http://dx.doi.org/10.1021/ac402941e
UT WoS 000329548700068
Keywords in English MALDI MS; ICP MS; single run; capillary electrophoresis
Tags kontrola MP, podil
Tags International impact, Reviewed
Changed by Changed by: prof. Mgr. Jan Preisler, Ph.D., učo 45329. Changed: 15/2/2018 22:11.
Abstract
In this work, a novel approach based on off-line coupling of a single run of capillary electrophoresis (CE) separation to both matrix-assisted laser desorption/ionization (MALDI) and substrate-assisted laser desorption inductively coupled plasma (SALD ICP) mass spectrometry (MS) is presented. Using a liquid junction and subatmospheric deposition chamber, CE fractions were extracted from a separation capillary and collected as 20-nL droplets on a custom-built polyethylene terephthalate glycol (PETG) target plate coated with a 10-nm gold layer which guaranteed compatibility with both MALDI and SALD ICP techniques. The MALDI matrix solution was then added to the produced spots. After it was dried, the separation record was consecutively analyzed in MALDI MS and ICP MS instruments. Thus, both proteomic and metallomic information was obtained off-line from a single CE run. The concept was demonstrated by the analysis of a mixture of rabbit liver metallothionein isoforms. In an additional study, the droplets representing the archived separation record were alternately mixed with two different MALDI matrices to obtain complementary information on both the apoproteins and their complexes with metals from a single separation run. The presented technique is a viable alternative to online coupling of column separation to electrospray MS and nebulizer ICP MS.
Links
ED1.1.00/02.0068, research and development projectName: CEITEC - central european institute of technology
EE2.3.30.0009, research and development projectName: Zaměstnáním čerstvých absolventů doktorského studia k vědecké excelenci
GAP206/12/0538, research and development projectName: Nové strategie úpravy vzorků pro desorpční hmotnostní spektrometrii
Investor: Czech Science Foundation
PrintDisplayed: 20/4/2024 01:13