FOLTYNOVÁ, Pavla, Antonín BEDNAŘÍK, Viktor KANICKÝ and Jan PREISLER. Diode laser thermal vaporization ICP MS with a simple tubular cell for determination of lead and cadmium in whole blood. Journal of Analytical Atomic Spectrometry. England: Royal Society of Chemistry, 2014, vol. 29, No 9, p. 1585-1590. ISSN 0267-9477. Available from: https://dx.doi.org/10.1039/C4JA00113C. |
Other formats:
BibTeX
LaTeX
RIS
@article{1196733, author = {Foltynová, Pavla and Bednařík, Antonín and Kanický, Viktor and Preisler, Jan}, article_location = {England}, article_number = {9}, doi = {http://dx.doi.org/10.1039/C4JA00113C}, keywords = {Diode laser thermal vaporization; DLTV; ICP MS; dried blood spot; lead; cadmium}, language = {eng}, issn = {0267-9477}, journal = {Journal of Analytical Atomic Spectrometry}, title = {Diode laser thermal vaporization ICP MS with a simple tubular cell for determination of lead and cadmium in whole blood}, url = {http://pubs.rsc.org/en/Content/ArticleLanding/2014/JA/C4JA00113C#!divAbstract}, volume = {29}, year = {2014} }
TY - JOUR ID - 1196733 AU - Foltynová, Pavla - Bednařík, Antonín - Kanický, Viktor - Preisler, Jan PY - 2014 TI - Diode laser thermal vaporization ICP MS with a simple tubular cell for determination of lead and cadmium in whole blood JF - Journal of Analytical Atomic Spectrometry VL - 29 IS - 9 SP - 1585-1590 EP - 1585-1590 PB - Royal Society of Chemistry SN - 02679477 KW - Diode laser thermal vaporization KW - DLTV KW - ICP MS KW - dried blood spot KW - lead KW - cadmium UR - http://pubs.rsc.org/en/Content/ArticleLanding/2014/JA/C4JA00113C#!divAbstract L2 - http://pubs.rsc.org/en/Content/ArticleLanding/2014/JA/C4JA00113C#!divAbstract N2 - A new low-cost device suitable for the recently presented sample introduction technique to inductively coupled plasma mass spectrometry (ICP MS), diode laser thermal vaporization (DLTV), is described. The device performance was optimized, compared to a commercial ablation system and applied to the determination of lead and cadmium in whole human blood without any sample treatment. A prearranged calibration set was printed on the paper strip using a piezoelectric dispenser. ER -
FOLTYNOVÁ, Pavla, Antonín BEDNAŘÍK, Viktor KANICKÝ and Jan PREISLER. Diode laser thermal vaporization ICP MS with a simple tubular cell for determination of lead and cadmium in whole blood. \textit{Journal of Analytical Atomic Spectrometry}. England: Royal Society of Chemistry, 2014, vol.~29, No~9, p.~1585-1590. ISSN~0267-9477. Available from: https://dx.doi.org/10.1039/C4JA00113C.
|