Accuracy of registration for fusion imaging with ultrasound navigation system
ANDRAŠINA, Tomáš, Ondřej KALA, Jakub FOUKAL and Vlastimil VÁLEKBasic information
Original name
Accuracy of registration for fusion imaging with ultrasound navigation system
Authors
Edition
CIRSE 2014, 2014
Other information
Language
English
Type of outcome
Prezentace na konferencích
Field of Study
30000 3. Medical and Health Sciences
Country of publisher
United Kingdom of Great Britain and Northern Ireland
Confidentiality degree
není předmětem státního či obchodního tajemství
Organization unit
Faculty of Medicine
Keywords in English
ultrasound navigation fusion
Změněno: 2/6/2015 15:57, Ing. Mgr. Věra Pospíšilíková
Abstract
V originále
Purpose The Philips iU22 PercuNav 4.0 (Koninklijke Philips Electronics N.V.) is an image navigation system, which provides real-time, three-dimensional visualization, and navigation tools for all stages of diagnosis and intervention. In this study, we analyze the accuracy of different registration methods for fusion imaging using the Percunav system on a phantom model. Material and Methods A preprocedural CT dataset was obtained using interventional triple modality phantom (Fluke Biomedical). Three different methods were used for the registration of real-time ultrasound images with CT datasets (registration patch match, ultrasound plane match, and US point match). For each method, variable distance of matching points to the target lesion was evaluated. Each subgroup fusion comprised 12 attempts with two operators. The real deviation of the target lesion depicted on CT scan and ultrasound in an anterior approach (approach for fusion), and the lateral approach were measured. Student’s t test and F test were used for statistical analyses. Results The real accuracy of CT fusion and ultrasound is not linearly dependent on the overall fit, counted by navigation systems after 3D data registration. US plane match registration is less time-consuming compared with 3 points match; it shows a good correlation between the overall fit and the target lesion in the anterior approach for distant lesions in the anterior and lateral approaches. There is a statistically significant difference in accuracy for depicting the target lesion from the anterior and lateral approaches (p<0.05). Conclusion All registration methods have comparable precision for targeting lesions in fusion imaging. Using different approaches for fusion registration and navigation could lead to significant inaccuracy of systems.