ZALUD, Ludek, Marketa KOTOVA, Petra KOCMANOVA, Petr DOBŠÁK a Jana KOLAROVA. Breath Analysis Using a Time-of-Flight Camera and Pressure Belts. Artificial Organs. Hoboken: Wiley-Blackwell, 2016, roč. 40, č. 6, s. 619-626. ISSN 0160-564X. Dostupné z: https://dx.doi.org/10.1111/aor.12592.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Breath Analysis Using a Time-of-Flight Camera and Pressure Belts
Autoři ZALUD, Ludek (203 Česká republika, garant), Marketa KOTOVA (203 Česká republika), Petra KOCMANOVA (203 Česká republika), Petr DOBŠÁK (203 Česká republika, domácí) a Jana KOLAROVA (203 Česká republika).
Vydání Artificial Organs, Hoboken, Wiley-Blackwell, 2016, 0160-564X.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30000 3. Medical and Health Sciences
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 2.403
Kód RIV RIV/00216224:14110/16:00089237
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1111/aor.12592
UT WoS 000378542100015
Klíčová slova anglicky Breath analysis; Range measurement; Calibration; Pressure measurement
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Mgr. Věra Pospíšilíková, učo 9005. Změněno: 25. 8. 2016 08:41.
Anotace
The proper way of breathing is important for everyone. Healthy people often do not follow respiration until breathing problems start—during stress or during sport activity in physiological cases. More serious cases are stroke, injury, or surgery of the chest and others. So, learning to breathe correctly and/or breathing diagnosis is considerable for many reasons. Two novel methods of breath analysis suitable for diagnostics and rehabilitation are presented. The first technique utilizes pressure belts fastened to the patient’s belly and chest, and the second method relies on a SwissRanger SR-4000 time-of-flight camera. The measurement principles are described together with the advantages and disadvantages of the applied techniques. The SwissRanger camera depth calibration is proposed to facilitate better results during the breath analysis. The methods are tested on a group of students to provide a comparison of their individual performances. As it was demonstrated, presented methods proved to work reliably. The method based on time-of-flight camera seems to be more suitable for diagnosis, while the method based on pressure belts is more suitable for rehabilitation and biofeedback applications.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
VytisknoutZobrazeno: 27. 7. 2024 13:59