HRUŠKOVÁ, Jana, Eva ZÁVODNÁ, Jiri MOUDR, Natasa HONZIKOVA and Bohumil FISER. Calculation of the Pulse Wave Velocity from the Waveform of the Central Aortic Pressure Pulse in Young Adults. In Alan Murray. Computing in Cardiology 2015. Washington: IEEE Computer Society, 2015, p. 385-388. ISSN 2325-8861.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Calculation of the Pulse Wave Velocity from the Waveform of the Central Aortic Pressure Pulse in Young Adults
Authors HRUŠKOVÁ, Jana (203 Czech Republic, guarantor, belonging to the institution), Eva ZÁVODNÁ (203 Czech Republic, belonging to the institution), Jiri MOUDR (203 Czech Republic), Natasa HONZIKOVA (203 Czech Republic) and Bohumil FISER (203 Czech Republic).
Edition Washington, Computing in Cardiology 2015, p. 385-388, 4 pp. 2015.
Publisher IEEE Computer Society
Other information
Original language English
Type of outcome Proceedings paper
Field of Study 30105 Physiology
Country of publisher United States of America
Confidentiality degree is not subject to a state or trade secret
Publication form printed version "print"
RIV identification code RIV/00216224:14110/15:00086487
Organization unit Faculty of Medicine
ISSN 2325-8861
Keywords in English Calculation of the Pulse Wave Velocity
Tags EL OK
Tags International impact, Reviewed
Changed by Changed by: Mgr. Vojtěch Juřík, Ph.D., učo 372092. Changed: 15/2/2019 00:04.
Abstract
Cardiovascular diseases are the most common causes of morbidity and mortality in developed countries. Therefore, the correct determination of the parameters indicating the disease condition is critical in effective treatment of patients [6, 10 - 12]. One of the parameters evaluating arterial stiffness is determining the pulse wave velocity (PWV), but the method of determining faces a number of problems. In the study was measured 20 healthy patients (15-23). Using applanation tonometry was measured pulse wave from a. radialis and a. carotis. PWV was measured by SphygmoCor and calculated by method of flow tringle using aortic pressure pulse for determination PWV. Average value of PWV calculated by method of flow triangle was 8.35 ± 0.86 m/ s and average value measured by SphygmoCor 7.2 ± 0.8 m/ s. The variance differences of measured and calculated values PWV was 0.785 ± 0.575 m /s. The average value of the a.radialisa. carotis distance was 485 ± 43.4 mm. According to the results it can be assumed that the new method of analysis the forward and backward waves is relatively accurate, but it is very sensitive to standardize measurement. The results are affected by several factors, is necessary to propose further steps to accurate protocol for the more precise results.
Links
MUNI/A/1326/2014, interní kód MUName: Kardiovaskulární systém od buňky k lůžku pacienta (Acronym: KASBUNPAC)
Investor: Masaryk University, Category A
PrintDisplayed: 30/4/2024 10:30