ZARITSKIY, S., B. OSMERA, František CVACHOVEC, M. MARIK, S. POSTA, V. RYPAR, D. RIAZANOV, V. LICHADEEV, Antonín KOLROS and Zdeněk MATĚJ. Neutron and Gamma Spectrometry in the Research Reactor LR-0. IEEE TRANSACTIONS ON NUCLEAR SCIENCE. PISCATAWAY: IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2015, vol. 62, No 3, p. 1212-1217. ISSN 0018-9499. Available from: https://dx.doi.org/10.1109/TNS.2015.2429747. |
Other formats:
BibTeX
LaTeX
RIS
@article{1344378, author = {Zaritskiy, S. and Osmera, B. and Cvachovec, František and Marik, M. and Posta, S. and Rypar, V. and Riazanov, D. and Lichadeev, V. and Kolros, Antonín and Matěj, Zdeněk}, article_location = {PISCATAWAY}, article_number = {3}, doi = {http://dx.doi.org/10.1109/TNS.2015.2429747}, keywords = {He-3 chamber; activation method; LR-0 reactor; neutron and gamma spectra; power distribution; power monitoring; spectrometry; stilbene; VVER mock-up}, language = {eng}, issn = {0018-9499}, journal = {IEEE TRANSACTIONS ON NUCLEAR SCIENCE}, title = {Neutron and Gamma Spectrometry in the Research Reactor LR-0}, volume = {62}, year = {2015} }
TY - JOUR ID - 1344378 AU - Zaritskiy, S. - Osmera, B. - Cvachovec, František - Marik, M. - Posta, S. - Rypar, V. - Riazanov, D. - Lichadeev, V. - Kolros, Antonín - Matěj, Zdeněk PY - 2015 TI - Neutron and Gamma Spectrometry in the Research Reactor LR-0 JF - IEEE TRANSACTIONS ON NUCLEAR SCIENCE VL - 62 IS - 3 SP - 1212-1217 EP - 1212-1217 PB - IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC SN - 00189499 KW - He-3 chamber KW - activation method KW - LR-0 reactor KW - neutron and gamma spectra KW - power distribution KW - power monitoring KW - spectrometry KW - stilbene KW - VVER mock-up N2 - The complex measurement system for the full-scale VVER models (mock-ups), created in the research reactor LR-0, is discussed. Fast neutron (energy from 0.5 to 10 MeV) and gamma spectra are measured in several representative points of the mock-ups by the two-parameter spectrometer with the cylindrical stilbene scintillation detectors. Measurements in the thermal and epithermal neutron region are carried out with the activation method using a broad set of activation monitors and with the He-3(n, p) counter. Activation measurements with threshold fast neutron detectors enlarge also the proton-recoil spectra measurements, such activation measurements are carried out especially in cases, when a spectrometer cannot be put in the necessary position. The core fission rate distribution is obtained by means of gamma-scanning of the fuel pins. The low noise precise power (flux density) monitoring system, independent of the operation control system, was developed in the LR-0 reactor for mock-up experiments. ER -
ZARITSKIY, S., B. OSMERA, František CVACHOVEC, M. MARIK, S. POSTA, V. RYPAR, D. RIAZANOV, V. LICHADEEV, Antonín KOLROS and Zdeněk MATĚJ. Neutron and Gamma Spectrometry in the Research Reactor LR-0. \textit{IEEE TRANSACTIONS ON NUCLEAR SCIENCE}. PISCATAWAY: IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2015, vol.~62, No~3, p.~1212-1217. ISSN~0018-9499. Available from: https://dx.doi.org/10.1109/TNS.2015.2429747.
|