J 2016

Dual carbonate sensor based on Eu(III) complex of DO3A ligand

VANĚK, Jakub, Filip SMRČKA, Přemysl LUBAL, Iveta TŘÍSKOVÁ, Libuše TRNKOVÁ et. al.

Basic information

Original name

Dual carbonate sensor based on Eu(III) complex of DO3A ligand

Authors

VANĚK, Jakub (203 Czech Republic, belonging to the institution), Filip SMRČKA (203 Czech Republic, belonging to the institution), Přemysl LUBAL (203 Czech Republic, guarantor, belonging to the institution), Iveta TŘÍSKOVÁ (203 Czech Republic, belonging to the institution) and Libuše TRNKOVÁ (203 Czech Republic, belonging to the institution)

Edition

Monatshefte für Chemie - Chemical Monthly, Wien, Springer-Verlag, 2016, 0026-9247

Other information

Language

English

Type of outcome

Článek v odborném periodiku

Field of Study

10406 Analytical chemistry

Country of publisher

Austria

Confidentiality degree

není předmětem státního či obchodního tajemství

References:

URL

Impact factor

Impact factor: 1.282

RIV identification code

RIV/00216224:14310/16:00087994

Organization unit

Faculty of Science

DOI

http://dx.doi.org/10.1007/s00706-016-1722-x

UT WoS

000374172200011

Keywords (in Czech)

luminiscenční sonda; elektrochemická sonda; uhličitany; Eu(III) komplexy; makrocyklický ligand

Keywords in English

luminiscence probe; electrochemical probe; carbonate; Eu(III) complexes; macrocyclic ligands

Tags

AKR, rivok
Změněno: 23/4/2020 17:41, Mgr. Marie Šípková, DiS.

Abstract

V originále

Eu(III) ternary complexes with 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (H(3)DO3A) and picolinate-like "antenna" ligands ([Eu(DO3A)(L)](-)) react with carbonate anion to form more stable [Eu(DO3A)(CO3)](2-) complexes which are non-fluorescent. Furthermore, [Eu(DO3A)(L)](-) and [Eu(DO3A)(CO3)](2-) differ in their electrochemical behavior. [Eu(DO3A)(L)](-) are therefore suggested as sensitive luminescence-based and also electrochemical sensors of carbonate anion. Both luminescence and voltammetric sensing strategies show similar analytical figures of merit (limit of detection 0.2 mM, dynamic range 0.2-1.6 mM). The voltammetric procedure was successfully tested in field conditions for the quantitative analysis of bicarbonate/carbonate in environmental water samples, utilizing portable potentiostat and screen-printed electrode.

Links

GA13-08336S, research and development project
Name: Hybridní materiály založené na makrocyklických ligandech pro využití v medicíně
Investor: Czech Science Foundation
LQ1601, research and development project
Name: CEITEC 2020 (Acronym: CEITEC2020)
Investor: Ministry of Education, Youth and Sports of the CR
ME09065, research and development project
Name: Výzkum nových detekčních systémů na bázi senzorových polí pro použití ve speciační analýze
Investor: Ministry of Education, Youth and Sports of the CR, Research of new detection systems based on sensor arrays for application in speciation analysis, Research and Development Programme KONTAKT (ME)
MUNI/A/1500/2015, interní kód MU
Name: Vývoj metod a instrumentace pro analýzu biologicky významných látek 2016
Investor: Masaryk University, Category A
Displayed: 12/11/2024 17:10