VANĚK, Jakub, Filip SMRČKA, Přemysl LUBAL, Iveta TŘÍSKOVÁ and Libuše TRNKOVÁ. Dual carbonate sensor based on Eu(III) complex of DO3A ligand. Monatshefte für Chemie - Chemical Monthly. Wien: Springer-Verlag, vol. 147, No 5, p. 925-934. ISSN 0026-9247. doi:10.1007/s00706-016-1722-x. 2016.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Dual carbonate sensor based on Eu(III) complex of DO3A ligand
Authors VANĚK, Jakub (203 Czech Republic, belonging to the institution), Filip SMRČKA (203 Czech Republic, belonging to the institution), Přemysl LUBAL (203 Czech Republic, guarantor, belonging to the institution), Iveta TŘÍSKOVÁ (203 Czech Republic, belonging to the institution) and Libuše TRNKOVÁ (203 Czech Republic, belonging to the institution).
Edition Monatshefte für Chemie - Chemical Monthly, Wien, Springer-Verlag, 2016, 0026-9247.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10406 Analytical chemistry
Country of publisher Austria
Confidentiality degree is not subject to a state or trade secret
WWW URL
Impact factor Impact factor: 1.282
RIV identification code RIV/00216224:14310/16:00087994
Organization unit Faculty of Science
Doi http://dx.doi.org/10.1007/s00706-016-1722-x
UT WoS 000374172200011
Keywords (in Czech) luminiscenční sonda; elektrochemická sonda; uhličitany; Eu(III) komplexy; makrocyklický ligand
Keywords in English luminiscence probe; electrochemical probe; carbonate; Eu(III) complexes; macrocyclic ligands
Tags AKR, rivok
Changed by Changed by: Mgr. Marie Šípková, DiS., učo 437722. Changed: 23/4/2020 17:41.
Abstract
Eu(III) ternary complexes with 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (H(3)DO3A) and picolinate-like "antenna" ligands ([Eu(DO3A)(L)](-)) react with carbonate anion to form more stable [Eu(DO3A)(CO3)](2-) complexes which are non-fluorescent. Furthermore, [Eu(DO3A)(L)](-) and [Eu(DO3A)(CO3)](2-) differ in their electrochemical behavior. [Eu(DO3A)(L)](-) are therefore suggested as sensitive luminescence-based and also electrochemical sensors of carbonate anion. Both luminescence and voltammetric sensing strategies show similar analytical figures of merit (limit of detection 0.2 mM, dynamic range 0.2-1.6 mM). The voltammetric procedure was successfully tested in field conditions for the quantitative analysis of bicarbonate/carbonate in environmental water samples, utilizing portable potentiostat and screen-printed electrode.
Links
GA13-08336S, research and development projectName: Hybridní materiály založené na makrocyklických ligandech pro využití v medicíně
Investor: Czech Science Foundation
LQ1601, research and development projectName: CEITEC 2020 (Acronym: CEITEC2020)
Investor: Ministry of Education, Youth and Sports of the CR
ME09065, research and development projectName: Výzkum nových detekčních systémů na bázi senzorových polí pro použití ve speciační analýze
Investor: Ministry of Education, Youth and Sports of the CR, Research of new detection systems based on sensor arrays for application in speciation analysis, Research and Development Programme KONTAKT (ME)
MUNI/A/1500/2015, interní kód MUName: Vývoj metod a instrumentace pro analýzu biologicky významných látek 2016
Investor: Masaryk University, Category A
PrintDisplayed: 20/4/2024 03:13