J 2016

Dual carbonate sensor based on Eu(III) complex of DO3A ligand

VANĚK, Jakub; Filip SMRČKA; Přemysl LUBAL; Iveta TŘÍSKOVÁ; Libuše TRNKOVÁ et. al.

Basic information

Original name

Dual carbonate sensor based on Eu(III) complex of DO3A ligand

Authors

VANĚK, Jakub (203 Czech Republic, belonging to the institution); Filip SMRČKA (203 Czech Republic, belonging to the institution); Přemysl LUBAL (203 Czech Republic, guarantor, belonging to the institution); Iveta TŘÍSKOVÁ (203 Czech Republic, belonging to the institution) and Libuše TRNKOVÁ (203 Czech Republic, belonging to the institution)

Edition

Monatshefte für Chemie - Chemical Monthly, Wien, Springer-Verlag, 2016, 0026-9247

Other information

Language

English

Type of outcome

Article in a journal

Field of Study

10406 Analytical chemistry

Country of publisher

Austria

Confidentiality degree

is not subject to a state or trade secret

References:

Impact factor

Impact factor: 1.282

RIV identification code

RIV/00216224:14310/16:00087994

Organization unit

Faculty of Science

UT WoS

000374172200011

EID Scopus

2-s2.0-84962300361

Keywords (in Czech)

luminiscenční sonda; elektrochemická sonda; uhličitany; Eu(III) komplexy; makrocyklický ligand

Keywords in English

luminiscence probe; electrochemical probe; carbonate; Eu(III) complexes; macrocyclic ligands

Tags

Changed: 23/4/2020 17:41, Mgr. Marie Novosadová Šípková, DiS.

Abstract

V originále

Eu(III) ternary complexes with 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (H(3)DO3A) and picolinate-like "antenna" ligands ([Eu(DO3A)(L)](-)) react with carbonate anion to form more stable [Eu(DO3A)(CO3)](2-) complexes which are non-fluorescent. Furthermore, [Eu(DO3A)(L)](-) and [Eu(DO3A)(CO3)](2-) differ in their electrochemical behavior. [Eu(DO3A)(L)](-) are therefore suggested as sensitive luminescence-based and also electrochemical sensors of carbonate anion. Both luminescence and voltammetric sensing strategies show similar analytical figures of merit (limit of detection 0.2 mM, dynamic range 0.2-1.6 mM). The voltammetric procedure was successfully tested in field conditions for the quantitative analysis of bicarbonate/carbonate in environmental water samples, utilizing portable potentiostat and screen-printed electrode.

Links

GA13-08336S, research and development project
Name: Hybridní materiály založené na makrocyklických ligandech pro využití v medicíně
Investor: Czech Science Foundation
LQ1601, research and development project
Name: CEITEC 2020 (Acronym: CEITEC2020)
Investor: Ministry of Education, Youth and Sports of the CR
ME09065, research and development project
Name: Výzkum nových detekčních systémů na bázi senzorových polí pro použití ve speciační analýze
Investor: Ministry of Education, Youth and Sports of the CR, Research of new detection systems based on sensor arrays for application in speciation analysis, Research and Development Programme KONTAKT (ME)
MUNI/A/1500/2015, interní kód MU
Name: Vývoj metod a instrumentace pro analýzu biologicky významných látek 2016
Investor: Masaryk University, Category A