J 2016

Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline

SHARMA, Vimal Kumar, David HYNEK, Libuše TRNKOVÁ, Dušan HEMZAL, Marian MÁRIK et. al.

Basic information

Original name

Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline

Authors

SHARMA, Vimal Kumar (356 India, belonging to the institution), David HYNEK (203 Czech Republic), Libuše TRNKOVÁ (203 Czech Republic, guarantor, belonging to the institution), Dušan HEMZAL (203 Czech Republic, belonging to the institution), Marian MÁRIK (703 Slovakia), René KIZEK (203 Czech Republic) and Jaromír HUBÁLEK (203 Czech Republic)

Edition

Microchimica Acta, Wien, Springer-Verlag, 2016, 0026-3672

Other information

Language

English

Type of outcome

Článek v odborném periodiku

Field of Study

10403 Physical chemistry

Country of publisher

Austria

Confidentiality degree

není předmětem státního či obchodního tajemství

References:

Impact factor

Impact factor: 4.580

RIV identification code

RIV/00216224:14310/16:00090238

Organization unit

Faculty of Science

UT WoS

000373146100003

Keywords (in Czech)

nanokompozit; senzor; cyklická voltametrie; diferenční pulzní voltametrie; skenovací elektronová mikroskopie; Ramanova spektroskopie

Keywords in English

nanocomposite; sensor; cyclic voltammetry; differential pulse voltammetry; scanning electron microscopy; Raman spectroscopy

Tags

Změněno: 23/4/2020 17:40, Mgr. Marie Šípková, DiS.

Abstract

V originále

The electrochemical behavior of adenine at a glassy carbon electrode (GCE) modified with a nanocomposite consisting of graphene oxide and polyaniline was investigated by cyclic voltammetry and differential pulse voltammetry. The nanocomposite was synthesized by polymerization and characterized by Raman and UV-vis spectroscopy, and its morphology was examined by scanning electron microscopy. Adenine is oxidized at the modified GCE at a working potential of 1.2 V (vs. Ag/AgCl) and gives a current density of approximately 2.64 nA.cm(-2), which is distinctly increased compared to the 0.57 nA.cm(-2) of a bare electrode. Peak current and adenine concentration are linearly related to each other in the range from 0.5 mu M to 20 mu M. The modified GCE exhibits acceptable analytical performance, with a detection limit of 72 nM and a limit of quantification of 240 nM. It is excellently reproducible, stable, and fabrication is simple.

Links

EE2.3.30.0009, research and development project
Name: Zaměstnáním čerstvých absolventů doktorského studia k vědecké excelenci
LH13053, research and development project
Name: Chemická a elektrochemická analýza purinových derivátů a jejich komplexů s mědí (Acronym: CECAP)
Investor: Ministry of Education, Youth and Sports of the CR