J 2016

Treatment of early localised infection of the Omniflow® II prosthesis with negative pressure wound therapy

KREJČÍ, Miroslav, Robert STAFFA and P. GLADIŠ

Basic information

Original name

Treatment of early localised infection of the Omniflow® II prosthesis with negative pressure wound therapy

Authors

KREJČÍ, Miroslav (203 Czech Republic, guarantor, belonging to the institution), Robert STAFFA (203 Czech Republic, belonging to the institution) and P. GLADIŠ (203 Czech Republic)

Edition

Wound Practice and Research, Osborne Park, Cambridge Publishing, 2016, 1837-6304

Other information

Language

English

Type of outcome

Článek v odborném periodiku

Field of Study

30200 3.2 Clinical medicine

Country of publisher

Australia

Confidentiality degree

není předmětem státního či obchodního tajemství

RIV identification code

RIV/00216224:14110/16:00088881

Organization unit

Faculty of Medicine

Keywords in English

Omniflow® II prosthesis; infection; wound therapy

Tags

Změněno: 12/9/2016 12:20, Ing. Mgr. Věra Pospíšilíková

Abstract

V originále

A biosynthetic vascular prosthesis is a special type of vascular graft. Implantation of this type of prosthesis can be considered for patients with limb ischaemia, diabetes mellitus, insufficient saphenous vein, and trophic ulcers. We present a rare case of successful healing of an early Szilagyi grade III vascular prosthetic infection in the groin using a topical negative pressure device and moist wound healing materials.

Links

NV15-33437A, research and development project
Name: Vliv edukace na vybrané psychosomatické faktory u pacientů indikovaných k implantaci cévní protézy