VOLNÝ, Ondřej, Petra CIMFLOVÁ, Pavla KADLECOVA, Petr VANĚK, Jiří VANÍČEK, Bijoy K. MENON and Robert MIKULÍK. Single-Phase Versus Multiphase CT Angiography in Middle Cerebral Artery Clot Detection-Benefits for Less Experienced Radiologists and Neurologists. Journal of Stroke & Cerebrovascular Diseases. Amsterdam: Elsevier Science Inc., 2017, vol. 26, No 1, p. 19-24. ISSN 1052-3057. Available from: https://dx.doi.org/10.1016/j.jstrokecerebrovasdis.2016.08.023.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Single-Phase Versus Multiphase CT Angiography in Middle Cerebral Artery Clot Detection-Benefits for Less Experienced Radiologists and Neurologists
Authors VOLNÝ, Ondřej (203 Czech Republic, belonging to the institution), Petra CIMFLOVÁ (203 Czech Republic, belonging to the institution), Pavla KADLECOVA (203 Czech Republic), Petr VANĚK (203 Czech Republic, belonging to the institution), Jiří VANÍČEK (203 Czech Republic, belonging to the institution), Bijoy K. MENON (124 Canada) and Robert MIKULÍK (203 Czech Republic, guarantor, belonging to the institution).
Edition Journal of Stroke & Cerebrovascular Diseases, Amsterdam, Elsevier Science Inc. 2017, 1052-3057.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 30103 Neurosciences
Country of publisher Netherlands
Confidentiality degree is not subject to a state or trade secret
Impact factor Impact factor: 1.598
RIV identification code RIV/00216224:14110/17:00095976
Organization unit Faculty of Medicine
Doi http://dx.doi.org/10.1016/j.jstrokecerebrovasdis.2016.08.023
UT WoS 000396430100013
Keywords in English Acute stroke; CT angiography; Distal clot; Middle cerebral artery; Multiphase CTA
Tags EL OK
Tags International impact, Reviewed
Changed by Changed by: Soňa Böhmová, učo 232884. Changed: 20/3/2018 11:46.
Abstract
Objectives: CT angiography (CTA) is recommended as a standard of stroke imaging. We investigated accuracy and precision of standard or single-phase CTA as compared with novel technique or multiphase CTA in clot detection in the middle cerebral artery. Methods: Twenty single-phase CTA and twenty multiphase CTA with prevailing M2 occlusion were assessed by 10 radiologists and 10 neurologists blinded to clinical information (7 less experienced and 3 experienced). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated as compared with reading by two seniors. Reliability was calculated using Krippendorff's alpha (K-alpha). Results: Sensitivity, specificity, PPV, and NPV of single-phase CTA compared with multiphase CTA for M2 clot presence were, respectively, .86, .75, .90, and .67 versus .88, .82, .92, and .72. For secondary or distal clots, sensitivity, specificity, PPV, and NPV of single-phase CTA compared with multiphase CTA were .41, .83, .50, and .78 versus .65, .77, .71, and .67. Agreement increased significantly in favor of multiphase CTA for detection of primary clots from moderate (.43) to substantial (.65) in less experienced radiologists and from slight (.10) to moderate (.30) in less experienced neurologists. Agreement significantly increased for distal or secondary clot detection in favor of multiphase CTA from fair (.24) to moderate (.49) in experienced radiologists and from slight (.12) to moderate (.46) in experienced neurologists. Conclusions: Multiphase CTA is a reliable imaging tool in M2 clot detection and might represent a beneficial imaging tool in clot detection for less experienced physicians.
PrintDisplayed: 25/7/2024 21:58