STÁREK, Zdeněk, František LEHAR, Jiří JEŽ, Martin ŠČUREK, Jiří WOLF, Tomáš KULÍK, Alena ŽBÁNKOVÁ a Miroslav NOVÁK. Three-dimensional rotational angiography of the left atrium and the oesophagus: the short-term mobility of the oesophagus and the stability of the fused three-dimensional model of the left atrium and the oesophagus during catheter ablation for atrial fibrillation. Europace. Oxford: Oxford University Press, 2017, roč. 19, č. 8, s. 1310-1316. ISSN 1099-5129. Dostupné z: https://dx.doi.org/10.1093/europace/euw187.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Three-dimensional rotational angiography of the left atrium and the oesophagus: the short-term mobility of the oesophagus and the stability of the fused three-dimensional model of the left atrium and the oesophagus during catheter ablation for atrial fibrillation
Autoři STÁREK, Zdeněk (203 Česká republika, garant, domácí), František LEHAR (203 Česká republika, domácí), Jiří JEŽ (203 Česká republika, domácí), Martin ŠČUREK (203 Česká republika, domácí), Jiří WOLF (203 Česká republika, domácí), Tomáš KULÍK (203 Česká republika, domácí), Alena ŽBÁNKOVÁ (203 Česká republika, domácí) a Miroslav NOVÁK (203 Česká republika, domácí).
Vydání Europace, Oxford, Oxford University Press, 2017, 1099-5129.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30201 Cardiac and Cardiovascular systems
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 5.231
Kód RIV RIV/00216224:14110/17:00095977
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1093/europace/euw187
UT WoS 000408340000008
Klíčová slova anglicky 3D; Rotational angiography of the left atrium and oesophagus; Image integration; Catheter ablation of atrial fibrillation; Mobility of the oesophagus; Atrioesophageal fistula
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 20. 3. 2018 15:33.
Anotace
Aims The objective of this study was to evaluate the mobility of the oesophagus and the stability of the three-dimensional (3D) model of the oesophagus using 3D rotational angiography (3DRA) of the left atrium (LA) and the oesophagus, fused with live fluoroscopy during catheter ablation for atrial fibrillation. Methods and results From March 2015 to September 2015, 3DRA of the LA and the oesophagus was performed in 33 patients before catheter ablation for atrial fibrillation. Control contrast oesophagography was performed every 30 min. The positions of the oesophagograms and the 3D model of the LA and the oesophagus were repeatedly measured and compared with the spine. The average shift of the oesophagus ranged from 2.7 ± 2.2 to 5.0 ± 3.5 mm. The average real-time oesophageal shift ranged from 2.7 ± 2.2 to 3.8 ± 3.4 mm. No significant shift was detected until the 90th minute of the procedure. The average shift of the 3D model of the LA and the oesophagus ranged from 1.4 ± 1.8 to 3.3 ± 3.0 mm (right–left direction) and from 0.9 ± 1.2 to 2.2 ± 1.3 mm (craniocaudal direction). During the 2 h procedure, there were no significant shifts of the model. Conclusion During catheter ablation for atrial fibrillation, there is no significant change in the position of the oesophagus until the 90th minute of the procedure and no significant shift in the 3D model of the LA and the oesophagus. The 3D model of the oesophagus reliably depicts the position of the oesophagus during the entire procedure.
Návaznosti
MUNI/A/1270/2015, interní kód MUNázev: Význam bioptické diagnostiky u nově vzniklé dilatační kardiomyopatie
Investor: Masarykova univerzita, Význam bioptické diagnostiky u nově vzniklé dilatační kardiomyopatie, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
VytisknoutZobrazeno: 25. 4. 2024 23:16