D 2017

Response of Ventricular Repolarization Parameters to Preload Changes in the Isolated Working Heart

HEJC, Jakub, Oto JANOUSEK, Marina RONZHINA, Tibor STRAČINA, Veronika OLEJNÍČKOVÁ et. al.

Základní údaje

Originální název

Response of Ventricular Repolarization Parameters to Preload Changes in the Isolated Working Heart

Autoři

HEJC, Jakub (203 Česká republika), Oto JANOUSEK (203 Česká republika), Marina RONZHINA (203 Česká republika), Tibor STRAČINA (703 Slovensko, domácí), Veronika OLEJNÍČKOVÁ (203 Česká republika, domácí), Jana KOLAROVA (203 Česká republika) a Marie NOVÁKOVÁ (203 Česká republika, garant, domácí)

Vydání

Washington, Computing in Cardiology 2016, od s. 409-412, 4 s. 2017

Nakladatel

IEEE Computer Society

Další údaje

Jazyk

angličtina

Typ výsledku

Stať ve sborníku

Obor

30105 Physiology

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Forma vydání

tištěná verze "print"

Kód RIV

RIV/00216224:14110/17:00094617

Organizační jednotka

Lékařská fakulta

ISBN

978-1-5090-0896-4

ISSN

UT WoS

000405710400103

Klíčová slova anglicky

Response of Ventricular Repolarization Parameters

Štítky

EL OK

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 13. 3. 2018 14:00, Soňa Böhmová

Anotace

V originále

Heart rate dependency of ventricular repolarization (VR) parameters has been a well known phenomenon for many years. Other contributing factors, such as Mechano-electric Coupling, are still under investigation. In this work, we analyze step response of VR parameters after abrupt change in mechanical end-diastolic load. 10 isolated rabbit hearts were perfused in Working Heart mode. The protocol consisted of abrupt changes in preload level of 3 cm/fcO. Left ventricle electric activity was recorded by seven unipolar leads at sampling frequency 10 kHz. A second-order transfer function model was used to identify basic parameters of Q.TEND and QTPEAK step responses, detected in reconstructed global pseudo-lead. Results show inverse relationship between changes in the preload and the length of QT related intervals. Increase of the preload causes significant (p<0.05) shortening of both intervals within the range of 1.6-26.9 ms. On the contrary, preload decreasing leads to prolongation of repolarization parameters, however, with significantly lower (p<0.05) average magnitude. Dynamic response is highly individual among each heart. Average time needed to reach stable QT in our data is 336.0 seconds, while min. and max. value is 41.4 and 894.0 seconds, respectively.

Návaznosti

GAP102/12/2034, projekt VaV
Název: Analýza vztahu mezi elektrickými ději a průtokem krve u srdečních komor
Investor: Grantová agentura ČR, Analýza vztahu mezi elektrickými ději a průtokem krve u srdečních komor
MUNI/A/1326/2014, interní kód MU
Název: Kardiovaskulární systém od buňky k lůžku pacienta (Akronym: KASBUNPAC)
Investor: Masarykova univerzita, Kardiovaskulární systém od buňky k lůžku pacienta, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
Zobrazeno: 4. 11. 2024 11:52