Další formáty:
BibTeX
LaTeX
RIS
@article{1371695, author = {Okeme, Joseph O. and Saini, Amandeep and Yang, Congqiao and Zhu, Jiping and Smedes, Foppe and Klánová, Jana and Diamond, Miriam L.}, article_location = {OXFORD (ENGLAND)}, article_number = {OCTOBER}, doi = {http://dx.doi.org/10.1016/j.atmosenv.2016.08.023}, keywords = {Passive sampling; Calibration; PDMS; XAD-Pocket; Phthalates; Flame-retardants}, language = {eng}, issn = {1352-2310}, journal = {Atmospheric Environment}, title = {Calibration of polydimethylsiloxane and XAD-Pocket passive air samplers (PAS) for measuring gas- and particle-phase SVOCs}, url = {http://www.sciencedirect.com/science/article/pii/S1352231016305933}, volume = {143}, year = {2016} }
TY - JOUR ID - 1371695 AU - Okeme, Joseph O. - Saini, Amandeep - Yang, Congqiao - Zhu, Jiping - Smedes, Foppe - Klánová, Jana - Diamond, Miriam L. PY - 2016 TI - Calibration of polydimethylsiloxane and XAD-Pocket passive air samplers (PAS) for measuring gas- and particle-phase SVOCs JF - Atmospheric Environment VL - 143 IS - OCTOBER SP - 202-208 EP - 202-208 PB - Pergamon Press SN - 13522310 KW - Passive sampling KW - Calibration KW - PDMS KW - XAD-Pocket KW - Phthalates KW - Flame-retardants UR - http://www.sciencedirect.com/science/article/pii/S1352231016305933 L2 - http://www.sciencedirect.com/science/article/pii/S1352231016305933 N2 - Polydimethylsiloxane (PDMS) has seen wide use as the stationary phase of gas chromatographic columns, a passive sampler in water, and recently as a personal exposure sampler, while styrene divinylbenzene copolymer (XAD) has been used extensively as a passive air sampler outdoors and indoors. We have introduced PDMS and XAD-Pocket as new indoor passive air samplers (PASs). The XAD-Pocket was designed to maximize the surface area-to-volume ratio of XAD and to minimize obstruction of air flow by the sampler housing. Methods were developed to expedite the use of these PASs for measuring phthalates, novel brominated flame-retardants (NFRs) and polybrominated diphenyl ethers (PBDEs) indoors. Sampling rates, Rs, (m(3) day(-1)), were measured during a 7-week calibration study. Variability within and between analyte groups was not statistically significant. As a result, generic values of 0.8 +/- 0.4 and 0.5 +/- 03 m(3) day(-1) dm(-2) are recommended for PDMS and XAD-Pocket for a 50-day deployment time, respectively. PDMS has a higher uptake rate and is easier to use than XAD-Pocket. ER -
OKEME, Joseph O., Amandeep SAINI, Congqiao YANG, Jiping ZHU, Foppe SMEDES, Jana KLÁNOVÁ a Miriam L. DIAMOND. Calibration of polydimethylsiloxane and XAD-Pocket passive air samplers (PAS) for measuring gas- and particle-phase SVOCs. \textit{Atmospheric Environment}. OXFORD (ENGLAND): Pergamon Press, 2016, roč.~143, OCTOBER, s.~202-208. ISSN~1352-2310. Dostupné z: https://dx.doi.org/10.1016/j.atmosenv.2016.08.023.
|