OTOUPALÍKOVÁ, Alena, Roman PROKEŠ, Zdeněk ŠIMEK a Branislav VRANA. In situ calibration of three passive samplers for the monitoring of steroid hormones in wastewater. Talanta. AMSTERDAM: Elsevier, 2016, roč. 161, December, s. 405-412. ISSN 0039-9140. Dostupné z: https://dx.doi.org/10.1016/j.talanta.2016.08.068.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název In situ calibration of three passive samplers for the monitoring of steroid hormones in wastewater
Autoři OTOUPALÍKOVÁ, Alena (203 Česká republika, domácí), Roman PROKEŠ (203 Česká republika, domácí), Zdeněk ŠIMEK (203 Česká republika, domácí) a Branislav VRANA (703 Slovensko, garant, domácí).
Vydání Talanta, AMSTERDAM, Elsevier, 2016, 0039-9140.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Nizozemské království
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.162
Kód RIV RIV/00216224:14310/16:00088653
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.talanta.2016.08.068
UT WoS 000386989500051
Klíčová slova anglicky Water monitoring; Steroid hormones; Passive sampling; Waste water; Chemcatcher; POCIS
Štítky AKR, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Andrea Mikešková, učo 137293. Změněno: 6. 4. 2017 19:32.
Anotace
In situ extraction of steroid hormones from waste water using adsorption-based integrative passive samplers represents a promising approach for their monitoring in water at ultra-trace concentrations. Three passive samplers, namely a POCIS, a Chemcatcher fitted with an Empore SDB-RPS disk, and an Empore SDB-RPS disk-based sampler with enhanced water flow, were calibrated in situ in treated municipal wastewater for the purpose of monitoring five estrogens (17-beta-estradiol, 17-alpha-estradiol, 17-alpha-ethinylestradiol, estrone and estriol) at sub ng per litre concentrations. Uptake of steroids to samplers during 14-day exposure in wastewater was compared with steroid concentrations in daily collected composite water samples. Sampling rates were obtained from a numerical solution of first order uptake kinetics equations describing the uptake of compounds into a passive sampler over time. Mass transfer of steroids in the Chemcatcher fitted with naked Empore disks was more than two times faster than in the POCIS sampler. The uptake capacity of the applied Empore disk was not sufficient for integrative uptake of all tested steroids during the entire 14-day exposure. Time-weighted average concentrations of steroids estimated at concentrations in units of ng L-1 using the in situ-calibrated samplers were within a factor of two from values obtained using composite water samples.
Návaznosti
GA13-20357S, projekt VaVNázev: Studium distribuce steroidních látek ve složkách pevných environmentálních matric.
Investor: Grantová agentura ČR, Studium distribuce steroidních látek ve složkách pevných environmentálních matric
LM2015051, projekt VaVNázev: Centrum pro výzkum toxických látek v prostředí (Akronym: RECETOX RI)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Výzkumná infrastruktura RECETOX
LO1214, projekt VaVNázev: Centrum pro výzkum toxických látek v prostředí (Akronym: RECETOX)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Centrum pro výzkum toxických látek v prostředí
VytisknoutZobrazeno: 24. 4. 2024 19:11