J 2016

Passive Sampling in Regulatory Chemical Monitoring of Nonpolar Organic Compounds in the Aquatic Environment

BOOIJ, Kees, Craig D. ROBINSON, Robert M. BURGESS, Philipp MAYER, Cindy A. ROBERTS et. al.

Základní údaje

Originální název

Passive Sampling in Regulatory Chemical Monitoring of Nonpolar Organic Compounds in the Aquatic Environment

Autoři

BOOIJ, Kees (528 Nizozemské království), Craig D. ROBINSON (826 Velká Británie a Severní Irsko), Robert M. BURGESS (826 Velká Británie a Severní Irsko), Philipp MAYER (208 Dánsko), Cindy A. ROBERTS (840 Spojené státy), Lutz AHRENS (752 Švédsko), Ian J. ALLAN (578 Norsko), Jan BRANT (826 Velká Británie a Severní Irsko), Lisa JONES (372 Irsko), Uta R. KRAUS (276 Německo), Martin M. LARSEN (208 Dánsko), Peter LEPOM (276 Německo), Joerdis PETERSEN (276 Německo), Daniel PROFROCK (276 Německo), Patrick ROOSE (56 Belgie), Sabine SCHAFER (276 Německo), Foppe SMEDES (528 Nizozemské království, garant, domácí), Celine TIXIER (250 Francie), Katrin VORKAMP (208 Dánsko) a Paul WHITEHOUSE (826 Velká Británie a Severní Irsko)

Vydání

ENVIRONMENTAL SCIENCE & TECHNOLOGY, WASHINGTON, AMER CHEMICAL SOC, 2016, 0013-936X

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30304 Public and environmental health

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Odkazy

URL

Impakt faktor

Impact factor: 6.198

Kód RIV

RIV/00216224:14310/16:00093454

Organizační jednotka

Přírodovědecká fakulta

DOI

http://dx.doi.org/10.1021/acs.est.5b04050

UT WoS

000367866300002

Klíčová slova anglicky

SOLID-PHASE MICROEXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; SEMIPERMEABLE-MEMBRANE DEVICES; QUASIMEME LABORATORY PERFORMANCE; FREELY DISSOLVED CONCENTRATIONS; PORE-WATER CONCENTRATIONS

Štítky

AKR, rivok

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 2. 3. 2017 12:07, Mgr. Michaela Hylsová, Ph.D.

Anotace

V originále

We reviewed compliance monitoring requirements in the European Union, the United States, and the Oslo-Paris Convention for the protection of the marine environment of the North-East Atlantic, and evaluated if these are met by passive sampling methods for nonpolar compounds. The strengths and shortcomings of passive sampling are assessed for water, sediments, and biota. Passive water sampling is a suitable technique for measuring concentrations of freely dissolved compounds. This method yields results that are incompatible with the EU's quality standard definition in terms of total concentrations in water, but this definition has little scientific basis. Insufficient quality control is a present weakness of passive sampling in water. Laboratory performance studies and the development of standardized methods are needed to improve data quality and to encourage the use of passive sampling by commercial laboratories and monitoring agencies. Successful prediction of bioaccumulation based on passive sampling is well documented for organisms at the lower trophic levels, but requires more research for higher levels. Despite the existence of several knowledge gaps, passive sampling presently is the best available technology for chemical monitoring of nonpolar organic compounds. Key issues to be addressed by scientists and environmental managers are outlined.

Návaznosti

LM2011028, projekt VaV
Název: RECETOX ? Národní infrastruktura pro výzkum toxických látek v prostředí
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, RECETOX Národní infrastruktura pro výzkum toxických látek v prostředí
LO1214, projekt VaV
Název: Centrum pro výzkum toxických látek v prostředí (Akronym: RECETOX)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Centrum pro výzkum toxických látek v prostředí
Zobrazeno: 6. 11. 2024 05:44