KOLÁŘOVÁ, Lenka, Lubomír PROKEŠ, Lukáš KUČERA, Aleš HAMPL, Eladia Maria PEŇA MENDÉZ, Petr VAŇHARA a Josef HAVEL. Clusters of Monoisotopic Elements for Calibration in (TOF) Mass Spectrometry. Journal of The American Society for Mass Spectrometry. New York: Springer, 2017, roč. 28, č. 3, s. 419-427. ISSN 1044-0305. Dostupné z: https://dx.doi.org/10.1007/s13361-016-1567-x.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Clusters of Monoisotopic Elements for Calibration in (TOF) Mass Spectrometry
Autoři KOLÁŘOVÁ, Lenka (203 Česká republika, domácí), Lubomír PROKEŠ (203 Česká republika, domácí), Lukáš KUČERA (203 Česká republika, domácí), Aleš HAMPL (203 Česká republika, domácí), Eladia Maria PEŇA MENDÉZ (724 Španělsko), Petr VAŇHARA (203 Česká republika, domácí) a Josef HAVEL (203 Česká republika, domácí).
Vydání Journal of The American Society for Mass Spectrometry, New York, Springer, 2017, 1044-0305.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.869
Kód RIV RIV/00216224:14310/17:00096268
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1007/s13361-016-1567-x
UT WoS 000398111400003
Klíčová slova anglicky Monoisotopic elements; Calibration; Gold clusters; Phosphorus clusters; TOF mass spectrometry
Štítky AKR, NZ, rivok
Změnil Změnila: Ing. Nicole Zrilić, učo 240776. Změněno: 30. 3. 2018 08:54.
Anotace
Precise calibration in TOF MS requires suitable and reliable standards, which are not always available for high masses. We evaluated inorganic clusters of the monoisotopic elements gold and phosphorus (Aun+/Aun- and Pn+/Pn-) as an alternative to peptides or proteins for the external and internal calibration of mass spectra in various experimental and instrumental scenarios. Monoisotopic gold or phosphorus clusters can be easily generated in situ from suitable precursors by laser desorption/ionization (LDI) or matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Their use offers numerous advantages, including simplicity of preparation, biological inertness, and exact mass determination even at lower mass resolution. We used citrate-stabilized gold nanoparticles to generate gold calibration clusters, and red phosphorus powder to generate phosphorus clusters. Both elements can be added to samples to perform internal calibration up to mass-to-charge (m/z) 10–15,000 without significantly interfering with the analyte. We demonstrated the use of the gold and phosphorous clusters in the MS analysis of complex biological samples, including microbial standards and total extracts of mouse embryonic fibroblasts. We believe that clusters of monoisotopic elements could be used as generally applicable calibrants for complex biological samples.
Návaznosti
EE2.3.20.0185, projekt VaVNázev: Centrum analýz a modelování tkání a orgánů
MUNI/A/1352/2015, interní kód MUNázev: Zdroje pro tkáňové inženýrství 6 (Akronym: TissueENG 6)
Investor: Masarykova univerzita, Zdroje pro tkáňové inženýrství 6, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
VytisknoutZobrazeno: 25. 4. 2024 10:20