COUFALÍKOVÁ, Kateřina, Iva BENEŠOVÁ, Tomáš VACULOVIČ, Viktor KANICKÝ a Jan PREISLER. LC coupled to ESI, MALDI and ICP MS - A multiple hyphenation for metalloproteomic studies. Analytica Chimica Acta. Amsterdam: Elsevier Science BV, roč. 968, May, s. 58-65. ISSN 0003-2670. doi:10.1016/j.aca.2017.03.016. 2017.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název LC coupled to ESI, MALDI and ICP MS - A multiple hyphenation for metalloproteomic studies
Autoři COUFALÍKOVÁ, Kateřina (203 Česká republika, domácí), Iva BENEŠOVÁ (203 Česká republika, domácí), Tomáš VACULOVIČ (203 Česká republika, domácí), Viktor KANICKÝ (203 Česká republika, domácí) a Jan PREISLER (203 Česká republika, garant, domácí).
Vydání Analytica Chimica Acta, Amsterdam, Elsevier Science BV, 2017, 0003-2670.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Nizozemské království
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 5.123
Kód RIV RIV/00216224:14310/17:00094859
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.aca.2017.03.016
UT WoS 000398436800006
Klíčová slova anglicky Matrix-assisted laser desorption/ionization; mass spectrometry; Inductively coupled plasma mass; spectrometry; Electrospray ionization mass spectrometry; Liquid chromatography; Metallothionein isoforms; Metal complexes
Štítky NZ, rivok
Změnil Změnila: Ing. Nicole Zrilić, učo 240776. Změněno: 6. 4. 2018 11:38.
Anotace
A new multiple detection arrangement for liquid chromatography (LC) that supplements conventional electrospray ionization (ESI) mass spectrometry (MS) detection with two complementary detection techniques, matrix-assisted laser desorption/ionization (MALDI) MS and substrate-assisted laser desorption inductively coupled plasma (SALD ICP) MS has been developed. The combination of the molecular and elemental detectors in a single separation run is accomplished by utilizing a commercial MALDI target made of conductive plastic. The proposed platform provides a number of benefits in today's metalloproteomic applications, which are demonstrated by analysis of a metallothionein mixture. To maintain metallothionein complexes, separation is carried out at a neutral pH. The effluent is split; a major portion is directed to ESI MS while the remaining 1.8% fraction is deposited onto a plastic MALDI target. Dried droplets are overlaid with MALDI matrix and analysed consecutively by MALDI MS and SALD ICP MS. In the ESI MS spectra, the MT isoform complexes with metals and their stoichiometry are determined; the apoforms are revealed in the MALDI MS spectra. Quantitative determination of metallothionein isoforms is performed via determination of metals in the complexes of the individual protein isoforms using SALD ICP MS. (C) 2017 Elsevier B.V. All rights reserved.
Návaznosti
GA15-05387S, projekt VaVNázev: Laserově desorpční hmotnostní spektrometrie pro analýzu molekul a nanočástic
Investor: Grantová agentura ČR, Laserově desorpční hmotnostní spektrometrie pro analýzu molekul a nanočástic
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
VytisknoutZobrazeno: 29. 3. 2024 00:16