BRICHTOVÁ, Eva a Jan ŠENKYŘÍK. SSh versus TSE sequence protocol in rapid MR examination of pediatric patients with programmable drainage system. Childs nervous system. NEW YORK: SPRINGER, roč. 33, č. 5, s. 753-758. ISSN 0256-7040. doi:10.1007/s00381-017-3385-2. 2017.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název SSh versus TSE sequence protocol in rapid MR examination of pediatric patients with programmable drainage system
Autoři BRICHTOVÁ, Eva (203 Česká republika, garant, domácí) a Jan ŠENKYŘÍK (203 Česká republika, domácí).
Vydání Childs nervous system, NEW YORK, SPRINGER, 2017, 0256-7040.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30103 Neurosciences
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 1.235
Kód RIV RIV/00216224:14110/17:00097343
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1007/s00381-017-3385-2
UT WoS 000403477000007
Klíčová slova anglicky Rapid magnetic resonance imaging; Susceptibility artifact; TSE sequence; Ventriculoperitoneal drainage; Pediatric patients
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 20. 3. 2018 16:21.
Anotace
Purpose A low radiation burden is essential during diagnostic procedures in pediatric patients due to their high tissue sensitivity. Using MR examination instead of the routinely used CT reduces the radiation exposure and the risk of adverse stochastic effects. Our retrospective study evaluated the possibility of using ultrafast single-shot (SSh) sequences and turbo spin echo (TSE) sequences in rapid MR brain imaging in pediatric patients with hydrocephalus and a programmable ventriculo peritoneal drainage system. Methods SSh sequences seem to be suitable for examining pediatric patients due to the speed of using this technique, but significant susceptibility artifacts due to the programmable drainage valve degrade the image quality. Therefore, a rapid MR examination protocol based on TSE sequences, less sensitive to artifacts due to ferromagnetic components, has been developed. Of 61 pediatric patients who were examined using MR and the SSh sequence protocol, a group of 15 patients with hydrocephalus and a programmable drainage system also underwent TSE sequence MR imaging. The susceptibility artifact volume in both rapid MR protocols was evaluated using a semiautomatic volumetry system. Results A statistically significant decrease in the susceptibility artifact volume has been demonstrated in TSE sequence imaging in comparison with SSh sequences. Using TSE sequences reduced the influence of artifacts from the programmable valve, and the image quality in all cases was rated as excellent. In all patients, rapid MR examinations were performed without any need for intravenous sedation or general anesthesia. Conclusions Our study results strongly suggest the superiority of the TSE sequence MR protocol compared to the SSh sequence protocol in pediatric patients with a programmable ventriculoperitoneal drainage system due to a significant reduction of susceptibility artifact volume. Both rapid sequence MR protocols provide quick and satisfactory brain imaging with no ionizing radiation and a reduced need for intravenous or general anesthesia.