HLAVÁČEK, Antonín, Miroslav PETEREK, Zdeněk FARKA, Matthias J. MICKERT, Leonhard PRECHTL, Dietmar KNOPP and Hans H. GORRIS. Rapid single-step upconversion-linked immunosorbent assay for diclofenac. Microchimica Acta. Vienna: Springer, 2017, vol. 184, No 10, p. 4159-4165. ISSN 0026-3672. Available from: https://dx.doi.org/10.1007/s00604-017-2456-0.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Rapid single-step upconversion-linked immunosorbent assay for diclofenac
Authors HLAVÁČEK, Antonín (203 Czech Republic, belonging to the institution), Miroslav PETEREK (203 Czech Republic, belonging to the institution), Zdeněk FARKA (203 Czech Republic, belonging to the institution), Matthias J. MICKERT (276 Germany), Leonhard PRECHTL (276 Germany), Dietmar KNOPP (276 Germany) and Hans H. GORRIS (276 Germany, guarantor).
Edition Microchimica Acta, Vienna, Springer, 2017, 0026-3672.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 10406 Analytical chemistry
Country of publisher Austria
Confidentiality degree is not subject to a state or trade secret
WWW URL
Impact factor Impact factor: 5.705
RIV identification code RIV/00216224:14740/17:00097559
Organization unit Central European Institute of Technology
Doi http://dx.doi.org/10.1007/s00604-017-2456-0
UT WoS 000410517400062
Keywords in English Bioconjugation; Electrophoretic purification; Immunoassay; Luminescence; Pharmaceutical micropollutant; Photon-upconversion
Tags CF CRYO, rivok
Tags International impact, Reviewed
Changed by Changed by: Mgr. Pavla Foltynová, Ph.D., učo 106624. Changed: 15/3/2018 11:03.
Abstract
The non-steroidal anti-inflammatory drug and analgesic diclofenac is a common micropollutant in water. A direct competitive upconversion-linked immunosorbent assay (ULISA) for diclofenac has been developed that is based on a nanoparticulate tracer consisting of a NaYF4:Yb,Er core (diameter of ~90 nm, excitation and emission wavelenghts 980 and 535 nm, respectively) enclosed by a carboxylated silica shell and finally coated with diclofenac-conjugated bovine gamma-globulin. The proteinaceous coating prevents non-specific adsorption of the tracer to the microtiter plate and provides a structurally flexible linker for surface-exposed diclofenac to warrant efficient competition with free (analyte) diclofenac in real water samples. The tracer was purified by gel electrophoresis and lyophilized. Both processes have no adverse effects on the immunoassay. All assay components can be stored in a dry state without a cooling chain, and can be reactivated on demand. Hence, this ULISA is well suited for environmental monitoring in low-resource settings. The ULISA has a similar limit of detection (20 pg mL-1; equivalent to 70 pM) as the conventional ELISA, but the time for analysis is reduced to 70 min because no enzymatic amplification steps are involved.
Links
LD15023, research and development projectName: Příprava diskrétních biokonjugátů photon-upconversion nanočástic
Investor: Ministry of Education, Youth and Sports of the CR
LM2015043, research and development projectName: Česká infrastruktura pro integrativní strukturní biologii (Acronym: CIISB)
Investor: Ministry of Education, Youth and Sports of the CR
PrintDisplayed: 14/5/2024 10:23