Other formats:
BibTeX
LaTeX
RIS
@article{1389407, author = {Hlaváček, Antonín and Peterek, Miroslav and Farka, Zdeněk and Mickert, Matthias J. and Prechtl, Leonhard and Knopp, Dietmar and Gorris, Hans H.}, article_location = {Vienna}, article_number = {10}, doi = {http://dx.doi.org/10.1007/s00604-017-2456-0}, keywords = {Bioconjugation; Electrophoretic purification; Immunoassay; Luminescence; Pharmaceutical micropollutant; Photon-upconversion}, language = {eng}, issn = {0026-3672}, journal = {Microchimica Acta}, title = {Rapid single-step upconversion-linked immunosorbent assay for diclofenac}, url = {https://link.springer.com/article/10.1007%2Fs00604-017-2456-0}, volume = {184}, year = {2017} }
TY - JOUR ID - 1389407 AU - Hlaváček, Antonín - Peterek, Miroslav - Farka, Zdeněk - Mickert, Matthias J. - Prechtl, Leonhard - Knopp, Dietmar - Gorris, Hans H. PY - 2017 TI - Rapid single-step upconversion-linked immunosorbent assay for diclofenac JF - Microchimica Acta VL - 184 IS - 10 SP - 4159-4165 EP - 4159-4165 PB - Springer SN - 00263672 KW - Bioconjugation KW - Electrophoretic purification KW - Immunoassay KW - Luminescence KW - Pharmaceutical micropollutant KW - Photon-upconversion UR - https://link.springer.com/article/10.1007%2Fs00604-017-2456-0 L2 - https://link.springer.com/article/10.1007%2Fs00604-017-2456-0 N2 - The non-steroidal anti-inflammatory drug and analgesic diclofenac is a common micropollutant in water. A direct competitive upconversion-linked immunosorbent assay (ULISA) for diclofenac has been developed that is based on a nanoparticulate tracer consisting of a NaYF4:Yb,Er core (diameter of ~90 nm, excitation and emission wavelenghts 980 and 535 nm, respectively) enclosed by a carboxylated silica shell and finally coated with diclofenac-conjugated bovine gamma-globulin. The proteinaceous coating prevents non-specific adsorption of the tracer to the microtiter plate and provides a structurally flexible linker for surface-exposed diclofenac to warrant efficient competition with free (analyte) diclofenac in real water samples. The tracer was purified by gel electrophoresis and lyophilized. Both processes have no adverse effects on the immunoassay. All assay components can be stored in a dry state without a cooling chain, and can be reactivated on demand. Hence, this ULISA is well suited for environmental monitoring in low-resource settings. The ULISA has a similar limit of detection (20 pg mL-1; equivalent to 70 pM) as the conventional ELISA, but the time for analysis is reduced to 70 min because no enzymatic amplification steps are involved. ER -
HLAVÁČEK, Antonín, Miroslav PETEREK, Zdeněk FARKA, Matthias J. MICKERT, Leonhard PRECHTL, Dietmar KNOPP and Hans H. GORRIS. Rapid single-step upconversion-linked immunosorbent assay for diclofenac. \textit{Microchimica Acta}. Vienna: Springer, 2017, vol.~184, No~10, p.~4159-4165. ISSN~0026-3672. Available from: https://dx.doi.org/10.1007/s00604-017-2456-0.
|