Other formats:
BibTeX
LaTeX
RIS
@article{1397072, author = {Nagy, Andrej and Lipoldová, Jolana and Novák, Miroslav and Štěpánová, Radka}, article_location = {AMSTERDAM}, article_number = {3}, doi = {http://dx.doi.org/10.1016/j.crvasa.2016.12.014}, keywords = {ICD; Ventricular fibrillation; Ventricular tachycardia; Remote monitoring; SCD predictors; Programmed ventricular stimulation}, language = {eng}, issn = {0010-8650}, journal = {Cor et Vasa}, title = {Occurrence of implantable cardioverter-defibrillator therapy in clinical practice}, url = {http://dx.doi.org/10.1016/j.crvasa.2016.12.014}, volume = {59}, year = {2017} }
TY - JOUR ID - 1397072 AU - Nagy, Andrej - Lipoldová, Jolana - Novák, Miroslav - Štěpánová, Radka PY - 2017 TI - Occurrence of implantable cardioverter-defibrillator therapy in clinical practice JF - Cor et Vasa VL - 59 IS - 3 SP - "E215"-"E221" EP - "E215"-"E221" PB - ELSEVIER SCIENCE BV SN - 00108650 KW - ICD KW - Ventricular fibrillation KW - Ventricular tachycardia KW - Remote monitoring KW - SCD predictors KW - Programmed ventricular stimulation UR - http://dx.doi.org/10.1016/j.crvasa.2016.12.014 L2 - http://dx.doi.org/10.1016/j.crvasa.2016.12.014 N2 - The landmark trials MADIT II, SCD-HeFT, and COMPANION in 2002-2005 years have reported their positive results to sudden cardiac death reduction. Since that time the indications for the use of implantable cardioverter-defibrillators (ICDs) have substantially broadened. The occurrence of appropriate ICD therapy differs in the individual trials. We were retrospectively analyzing the occurrence of ventricular tachycardia/ventricular fibrillation (VT/VF) from ICD remote monitoring database (Biotronik Home Monitoring TM, www.biotronik-homemonitoring.com). No significant difference was found between subgroups divided by the implantation indication, the programmed ventricular stimulation, the aggressivity of programmed ventricular stimulation protocol, left ventricular ejection fraction, ICD types, percentage of right ventricular pacing, diabetes mellitus, renal dysfunction and gender. VT/VF occurred statistically significantly more often in patients with non-sustained VT on the preimplant Holter monitoring report in patients with primary preventive indication for postinfarction coronary artery disease but not in primary preventive indication for non-ischemic dilated cardiomyopathy. We observed higher VT/VF occurrence in patients with preimplant syncope or presyncope even higher than in patients after cardiopulmonary resuscitation. There was a visible trend for higher VT/VF occurrence in patients with positive programmed ventricular stimulation especially with less aggressive protocol and in patients with left ventricular ejection fraction of 30% and less. Authors found the preimplant nonsustained ventricular tachycardia (NSVT) on Holter monitoring as the only independent predictor of VT/VF occurrence. (C) 2017 The Czech Society of Cardiology. Published by Elsevier Sp. zo.o. All rights reserved. ER -
NAGY, Andrej, Jolana LIPOLDOVÁ, Miroslav NOVÁK and Radka ŠTĚPÁNOVÁ. Occurrence of implantable cardioverter-defibrillator therapy in clinical practice. \textit{Cor et Vasa}. AMSTERDAM: ELSEVIER SCIENCE BV, 2017, vol.~59, No~3, p.~''E215''-''E221'', 7 pp. ISSN~0010-8650. Available from: https://dx.doi.org/10.1016/j.crvasa.2016.12.014.
|