MASNER, Petr, Barbora JAVŮRKOVÁ a Luděk BLÁHA. Rapid in situ toxicity testing with luminescent bacteria Photorhabdus luminescens and Vibrio fischeri adapted to a small portable luminometer. Environmental Science and Pollution Research. HEIDELBERG: SPRINGER HEIDELBERG, roč. 24, č. 4, s. 3748-3758. ISSN 0944-1344. doi:10.1007/s11356-016-8096-9. 2017.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Rapid in situ toxicity testing with luminescent bacteria Photorhabdus luminescens and Vibrio fischeri adapted to a small portable luminometer
Autoři MASNER, Petr (203 Česká republika, domácí), Barbora JAVŮRKOVÁ (203 Česká republika, domácí) a Luděk BLÁHA (203 Česká republika, garant, domácí).
Vydání Environmental Science and Pollution Research, HEIDELBERG, SPRINGER HEIDELBERG, 2017, 0944-1344.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10511 Environmental sciences
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.800
Kód RIV RIV/00216224:14310/17:00100220
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1007/s11356-016-8096-9
UT WoS 000397004600045
Klíčová slova anglicky Photorhabdus luminescens; Vibrio fisheri; Whole effluent testing (WET); In situ testing; Portable biotest
Štítky NZ, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Nicole Zrilić, učo 240776. Změněno: 11. 4. 2018 11:06.
Anotace
The present study demonstrates development of a rapid testing protocol based on a small portable luminometer using flash kinetic assessment of bacterial bioluminescence. The laboratory comparisons based on six model organic toxicants and two metals showed significant correlations between responses of freshwater bacteria Photorhabdus luminescens and standard marine bacterial species Vibrio fisheri. While P. luminescens was less sensitive in standard arrangements, the responses of both organisms were comparable in the newly introduced portable luminometer setup. The applicability and reproducibility of the portable luminometer protocol was further demonstrated in the assessment of 43 European wastewater effluents that were simultaneously tested for toxicity and analysed for 150 organic and 20 inorganic contaminants grouped into 13 major chemical classes. Clear association between the toxic responses in both compared bacterial species and the elevated levels of inorganic compounds (toxic metals), chlorophenols and benzotriazole anticorrosives was observed. The new protocol with a portable luminometer provides a fast (30 s) response and may be used as a tool for rapid in situ toxicity evaluation of freshwater environmental samples such as effluents.
Návaznosti
ED2.1.00/19.0382, projekt VaVNázev: CETOCOEN UPgrade
LO1214, projekt VaVNázev: Centrum pro výzkum toxických látek v prostředí (Akronym: RECETOX)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Centrum pro výzkum toxických látek v prostředí
VytisknoutZobrazeno: 20. 4. 2024 01:58