Informační systém MU
SHAGIN, D.A., I.A. SHAGINA, A.R. ZARETSKY, E.V. BARSOVA, I.V. KELMANSON, S. LUKYANOV, Dmitriy CHUDAKOV a Mikhail SHUGAY. A high-throughput assay for quantitative measurement of PCR errors. Scientific reports. LONDON: NATURE PUBLISHING GROUP, 2017, roč. 7, JUN, s. 2718-2728. ISSN 2045-2322. Dostupné z: https://dx.doi.org/10.1038/s41598-017-02727-8.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název A high-throughput assay for quantitative measurement of PCR errors
Autoři SHAGIN, D.A. (643 Rusko), I.A. SHAGINA (643 Rusko), A.R. ZARETSKY (643 Rusko), E.V. BARSOVA (643 Rusko), I.V. KELMANSON (643 Rusko), S. LUKYANOV (643 Rusko), Dmitriy CHUDAKOV (643 Rusko, garant, domácí) a Mikhail SHUGAY (643 Rusko, domácí).
Vydání Scientific reports, LONDON, NATURE PUBLISHING GROUP, 2017, 2045-2322.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10609 Biochemical research methods
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.122
Kód RIV RIV/00216224:14740/17:00100340
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1038/s41598-017-02727-8
UT WoS 000402515800036
Klíčová slova anglicky DRUG-RESISTANCE MUTATIONS; DNA-POLYMERASE; RARE MUTATIONS; FIDELITY; AMPLIFICATION; SPECIFICITY
Štítky OA, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 13. 3. 2018 14:12.
Anotace
The accuracy with which DNA polymerase can replicate a template DNA sequence is an extremely important property that can vary by an order of magnitude from one enzyme to another. The rate of nucleotide misincorporation is shaped by multiple factors, including PCR conditions and proofreading capabilities, and proper assessment of polymerase error rate is essential for a wide range of sensitive PCR-based assays. In this paper, we describe a method for studying polymerase errors with exceptional resolution, which combines unique molecular identifier tagging and high-throughput sequencing. Our protocol is less laborious than commonly-used methods, and is also scalable, robust and accurate. In a series of nine PCR assays, we have measured a range of polymerase accuracies that is in line with previous observations. However, we were also able to comprehensively describe individual errors introduced by each polymerase after either 20 PCR cycles or a linear amplification, revealing specific substitution preferences and the diversity of PCR error frequency profiles. We also demonstrate that the detected high-frequency PCR errors are highly recurrent and that the position in the template sequence and polymerase-specific substitution preferences are among the major factors influencing the observed PCR error rate.
Návaznosti
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
Zobrazeno: 29. 7. 2024 00:20