HRBÁČ, Jan, David NOVÁK, Petr KNOPF, Marek ŠVARC a Jan VACEK. Carbon fiber on-line detector for monitoring human blood serum reductive capacity. A complex technical solution. Online. Journal of Electroanalytical Chemistry. Lausanne: Elsevier, 2018, roč. 814, April 1, s. 184-191. ISSN 1572-6657. Dostupné z: https://dx.doi.org/10.1016/j.jelechem.2018.02.037. [citováno 2024-04-24]
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Carbon fiber on-line detector for monitoring human blood serum reductive capacity. A complex technical solution
Autoři HRBÁČ, Jan (203 Česká republika, garant, domácí), David NOVÁK (203 Česká republika), Petr KNOPF (203 Česká republika), Marek ŠVARC (203 Česká republika) a Jan VACEK (203 Česká republika)
Vydání Journal of Electroanalytical Chemistry, Lausanne, Elsevier, 2018, 1572-6657.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10405 Electrochemistry
Stát vydavatele Nizozemské království
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.218
Kód RIV RIV/00216224:14310/18:00102472
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.jelechem.2018.02.037
UT WoS 000429394500024
Klíčová slova anglicky Carbon fiber Microelectrode On-line sensing Amperometry Clinical sample Trolox
Změnil Změnil: Mgr. Michal Petr, učo 65024. Změněno: 23. 4. 2024 11:11.
Anotace
The construction of a cylindrical carbon fiber on-line detector is presented, featuring a novel way of sealing the carbon fiber microelectrode, the design of an interchangeable carbon fiber microelectrode-based flow cell and its interface with data acquisition electronics. The two-electrode setup was used, where the regeneration of the carbon fiber working electrode surface between analyses was performed using an electrochemical procedure, typically -1/+1V potential cycling. The detector was incorporated into the flow injection analysis manifold and the applicability of the developed sensing platform tested for monitoring a hexacyanoferrate (II/III) redox probe and the oxidizable compounds trolox (6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid), uric acid, and l-ascorbic acid, with dehydroascorbic acid as a negative control. Finally, the optimized procedure was utilized for the analysis of human blood serum reductive (antioxidant) capacity based on amperometric sensing and flow injection analysis at a flow rate of 10ul/min. Amperometric responses for blood serum samples were evaluated for standard deviation, whose average value was estimated to be ±0.3nA (n=20). The electrolytic efficiency of the detector was on the order of % units, e.g. 2% for trolox. The flow cell geometry and application of carbon fiber electrodes resulted in the absence of dead volumes and passivation phenomena, in contrast to conventional high-surface-area electrochemical cells. We suppose that the complex technical solution presented here could find a broad range of applications in the on-line monitoring of other reducing low-molecular bioactives and of the redox properties of various body fluids or clinical samples.