DOSTÁL, Marek, Miloš KEŘKOVSKÝ, Eva KORIŤÁKOVÁ, Eva NĚMCOVÁ, Jakub STULÍK, Monika STAŇKOVÁ a Vladan BERNARD. Analysis of diffusion tensor measurements of the human cervical spinal cord based on semiautomatic segmentation of the white and gray matter. Journal of Magnetic Resonance Imaging. Hoboken: Wiley, roč. 48, č. 5, s. 1217-1227. ISSN 1053-1807. doi:10.1002/jmri.26166. 2018.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Analysis of diffusion tensor measurements of the human cervical spinal cord based on semiautomatic segmentation of the white and gray matter
Autoři DOSTÁL, Marek (203 Česká republika, domácí), Miloš KEŘKOVSKÝ (203 Česká republika, garant, domácí), Eva KORIŤÁKOVÁ (203 Česká republika, domácí), Eva NĚMCOVÁ (203 Česká republika), Jakub STULÍK (203 Česká republika, domácí), Monika STAŇKOVÁ (203 Česká republika, domácí) a Vladan BERNARD (203 Česká republika, domácí).
Vydání Journal of Magnetic Resonance Imaging, Hoboken, Wiley, 2018, 1053-1807.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30224 Radiology, nuclear medicine and medical imaging
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.732
Kód RIV RIV/00216224:14110/18:00106924
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1002/jmri.26166
UT WoS 000448081300006
Klíčová slova anglicky ITK-SNAP; Spinal Cord Toolbox; diffusion tensor imaging; gray and white matter segmentation; spinal cord segmentation
Štítky 14110216, 14110511, 14119612, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 9. 2. 2019 20:24.
Anotace
BackgroundPurposeSegmentation of the gray and white matter (GM, WM) of the human spinal cord in MRI images as well as the analysis of spinal cord diffusivity are challenging. When appropriately segmented, diffusion tensor imaging (DTI) of the spinal cord might be beneficial in the diagnosis and prognosis of several diseases. To evaluate the applicability of a semiautomatic algorithm provided by ITK-SNAP in classification mode (CLASS) for segmenting cervical spinal cord GM, WM in MRI images and analyzing DTI parameters. Study TypeSubjectsProspective. Twenty healthy volunteers. SequencesAssessment1.5T, turbo spin echo, fast field echo, single-shot echo planar imaging. Three raters segmented the tissues by manual, CLASS, and atlas-based methods (Spinal Cord Toolbox, SCT) on T-2-weighted and DTI images. Masks were quantified by similarity and distance metrics, then analyzed for repeatability and mutual comparability. Masks created over T-2 images were registered into diffusion space and fractional anisotropy (FA) values were statistically evaluated for dependency on method, rater, or tissue. Statistical TestsResultst-test, analysis of variance (ANOVA), coefficient of variation, Dice coefficient, Hausdorff distance. CLASS segmentation reached better agreement with manual segmentation than did SCT (P<0.001). Intra- and interobserver repeatability of SCT was better for GM and WM (both P<0.001) but comparable with CLASS in entire spinal cord segmentation (P=0.17 and P=0.07, respectively). While FA values of whole spinal cord were not influenced by choice of segmentation method, both semiautomatic methods yielded lower FA values (P<0.005) for GM than did the manual technique (mean differences 0.02 and 0.04 for SCT and CLASS, respectively). Repeatability of FA values for all methods was sufficient, with mostly less than 2% variance.
Návaznosti
MUNI/A/1464/2014, interní kód MUNázev: Pokročilé techniky analýzy dat MR zobrazení tenzorů difuze míchy u pacientů s roztroušenou sklerózou
Investor: Masarykova univerzita, Pokročilé techniky analýzy dat MR zobrazení tenzorů difuze míchy u pacientů s roztroušenou sklerózou, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
NV15-32133A, projekt VaVNázev: Predikce konverze klinicky izolovaného syndromu do roztroušené sklerózy pomocí pokročilých technik zobrazení magnetickou rezonancí
VytisknoutZobrazeno: 20. 4. 2024 02:08