LOSA, E., M. KOŠŤÁL, V. RYPAR, M. SCHULC, E. NOVÁK, B. JÁNSKÝ, Martin VEŠKRNA, Filip MRAVEC, Zdeněk MATĚJ a František CVACHOVEC. Benchmarking of the graphite and fluoride insertions in LR-0 reactor. In Physics of Reactors 2016, PHYSOR 2016: Unifying Theory and Experiments in the 21st Century. United States: American Nuclear Society. s. 1259-1270. ISBN 978-1-5108-2573-4. 2016.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Benchmarking of the graphite and fluoride insertions in LR-0 reactor
Autoři LOSA, E. (203 Česká republika), M. KOŠŤÁL (203 Česká republika), V. RYPAR (203 Česká republika), M. SCHULC (203 Česká republika), E. NOVÁK (203 Česká republika), B. JÁNSKÝ (203 Česká republika), Martin VEŠKRNA (203 Česká republika, domácí), Filip MRAVEC (203 Česká republika, domácí), Zdeněk MATĚJ (203 Česká republika, garant, domácí) a František CVACHOVEC (203 Česká republika).
Vydání United States, Physics of Reactors 2016, PHYSOR 2016: Unifying Theory and Experiments in the 21st Century, od s. 1259-1270, 12 s. 2016.
Nakladatel American Nuclear Society
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 10304 Nuclear physics
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Forma vydání tištěná verze "print"
WWW URL
Kód RIV RIV/00216224:14330/16:00101854
Organizační jednotka Fakulta informatiky
ISBN 978-1-5108-2573-4
Klíčová slova anglicky Benchmark; FLIBE; FLINA; Graphite; LR-0
Změnil Změnil: RNDr. Pavel Šmerk, Ph.D., učo 3880. Změněno: 30. 4. 2019 07:32.
Anotace
Graphite and selected fluoride salts have their place in historic, as well as in most advanced nuclear reactors. Integral benchmarking of materials used in nuclear technology is very important for validation of calculation codes used at advanced reactor modelling. Discovered discrepancies can also point at inaccurate description of nuclear data. Benchmark experiments have been carried out in zero power light water reactor, LR-0, which is suited for these tasks thanks to the well-defined criticality. Criticality and neutron spectrum in graphite and fluoride salt has been benchmarked in experimental phase. The results of critical benchmark for graphite are showing good coincidence with calculation in ENDF/B-VII.0 nuclear library, however discrepancies exceeding 3a interval of uncertainties have been demonstrated with fluoride salt. Large discrepancies are apparent from C/E-1 comparison of neutron spectrum in fluoride salt. These discrepancies are likely caused by improper description of 19F.
Návaznosti
TA01011383, projekt VaVNázev: Digitální spektrometrický systém jaderného záření
VytisknoutZobrazeno: 20. 4. 2024 11:07