WILDI, K., H. SINGEISEN, R. TWERENBOLD, P. BADERTSCHER, D. WUSSLER, L.J.J. KLINKENBERG, S.J.R. MEEX, T. NESTELBERGER, J. BOEDDINGHAUS, O. MIRO, F.J. MARTIN-SANCHEZ, B. MORAWIEC, P. MUZYK, Jiří PAŘENICA, D.I. KELLER, N. GEIGY, E. POTLUKOVA, Z. SABTI, N. KOZHUHAROV, C. PUELACHER, J.D. de LAVALLAZ, M.R. GIMENEZ, S. SHRESTHA, G. MARZANO, K. RENTSCH, S. OSSWALD, T. REICHLIN a C. MUELLER. Circadian rhythm of cardiac troponin I and its clinical impact on the diagnostic accuracy for acute myocardial infarction. International Journal of Cardiology. Clare: Elsevier Ireland Ltd., roč. 270, NOV 1 2018, s. 14-20. ISSN 0167-5273. doi:10.1016/j.ijcard.2018.05.136. 2018.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Circadian rhythm of cardiac troponin I and its clinical impact on the diagnostic accuracy for acute myocardial infarction
Autoři WILDI, K. (756 Švýcarsko), H. SINGEISEN (756 Švýcarsko), R. TWERENBOLD (756 Švýcarsko), P. BADERTSCHER (756 Švýcarsko), D. WUSSLER (756 Švýcarsko), L.J.J. KLINKENBERG (528 Nizozemské království), S.J.R. MEEX (528 Nizozemské království), T. NESTELBERGER (756 Švýcarsko), J. BOEDDINGHAUS (756 Švýcarsko), O. MIRO (724 Španělsko), F.J. MARTIN-SANCHEZ (724 Španělsko), B. MORAWIEC (616 Polsko), P. MUZYK (616 Polsko), Jiří PAŘENICA (203 Česká republika, domácí), D.I. KELLER (756 Švýcarsko), N. GEIGY (756 Švýcarsko), E. POTLUKOVA (756 Švýcarsko), Z. SABTI (756 Švýcarsko), N. KOZHUHAROV (756 Švýcarsko), C. PUELACHER (756 Švýcarsko), J.D. de LAVALLAZ (756 Švýcarsko), M.R. GIMENEZ (756 Švýcarsko), S. SHRESTHA (756 Švýcarsko), G. MARZANO (756 Švýcarsko), K. RENTSCH (756 Švýcarsko), S. OSSWALD (756 Švýcarsko), T. REICHLIN (756 Švýcarsko) a C. MUELLER (756 Švýcarsko, garant).
Vydání International Journal of Cardiology, Clare, Elsevier Ireland Ltd. 2018, 0167-5273.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30201 Cardiac and Cardiovascular systems
Stát vydavatele Irsko
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 3.471
Kód RIV RIV/00216224:14110/18:00104226
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1016/j.ijcard.2018.05.136
UT WoS 000444609000003
Klíčová slova anglicky Acute myocardial infarction; Diagnosis; High-sensitivity cardiac troponin I; Circadian rhythm
Štítky 14110211, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 9. 2. 2019 21:23.
Anotace
Background: High-sensitivity cardiac troponin T (hs-cTnT) blood concentrationswere shown to exhibit a diurnal rhythm, characterized by gradually decreasing concentrations throughout daytime, rising concentrations during nighttime and peak concentrations in the morning. We aimed to investigate whether this also applies to (h)s-cTnI assays and whether it would affect diagnostic accuracy for acute myocardial infarction (AMI). Methods: Blood concentrations of cTnI were measured at presentation and after 1 h using four different cTnI assays: three commonly used sensitive (s-cTnI Architect, Ultra and Accu) and one experimental high-sensitivity assay (hs-cTnI Accu) in a prospective multicenter diagnostic study of patients presenting to the emergency department with suspected AMI. These concentrations and their diagnostic accuracy for AMI (quantified by the area under the curve (AUC)) were compared between morning (11 p.m. to 2 p.m.) and evening (2 p.m. to 11 p. m.) presenters. Results: Among 2601 patients, AMI was the final diagnosis in 17.6% of patients. Concentrations of (h) s-cTnI as measured using all four assayswere comparable in patients presenting in themorning versus patients presenting in the evening. Diagnostic accuracy for AMI of all four (h) s-cTnI assays were high and comparable between patients presenting in the morning versus presenting in the evening (AUC at presentation: 0.90 vs 0.93 for s-cTnI Architect; 0.91 vs 0.94 for s-cTnI Ultra; 0.89 vs 0.94 for s-cTnI Accu; 0.91 vs 0.94 for hs-cTnI Accu). Conclusions: Cardiac TnI does not seemto express a diurnal rhythm. Diagnostic accuracy for AMI is very high and does not differ with time of presentation. Clinical trial registration: NCT00470587, http://clinicaltrials.gov/show/NCT00470587 (c) 2018 Elsevier B.V. All rights reserved.
VytisknoutZobrazeno: 29. 3. 2024 12:23