HOMZA, Miroslav, Ondrej MACHACZKA, Martin PORZER, Milan KOZÁK, Jiri PLASEK a David SIPULA. Comparison of different methods of ABI acquisition for detection of peripheral artery disease in diabetic patients. Biomedical papers. Olomouc: Palacky University, roč. 163, č. 3, s. 227-232. ISSN 1213-8118. doi:10.5507/bp.2018.046. 2019.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Comparison of different methods of ABI acquisition for detection of peripheral artery disease in diabetic patients
Autoři HOMZA, Miroslav (203 Česká republika), Ondrej MACHACZKA (203 Česká republika), Martin PORZER (203 Česká republika), Milan KOZÁK (203 Česká republika, domácí), Jiri PLASEK (203 Česká republika) a David SIPULA (203 Česká republika).
Vydání Biomedical papers, Olomouc, Palacky University, 2019, 1213-8118.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30201 Cardiac and Cardiovascular systems
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 1.000
Kód RIV RIV/00216224:14110/19:00108957
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.5507/bp.2018.046
UT WoS 000489991000006
Klíčová slova anglicky ankle brachial index; diabetes; oscillometric measurement; dopplerometric measurement; duplex ultrasonography
Štítky 14110211, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 17. 12. 2019 07:54.
Anotace
Background: Ankle brachial index (ABI) is the principal screening method for peripheral arterial disease (PAD). In this study, we compare various types of Doppler-derived and oscillometric ABIs with results obtained through duplex ultrasonography. Methods: 62 patients were enrolled in the study. For each limb, blood pressures for both ankle arteries and the arm were measured using Doppler and an automated oscillometric device. Duplex ultrasound was performed for all limbs and occlusions >50% were considered PAD-positive. ABI was calculated using both higher (HABP) and lower (LABP) arterial blood pressure on the individual limbs and the ability to predict duplex-detected stenoses was evaluated. Results: LABP calculation provided results superior to the guideline-recommended HABP. Considering patients with ABI >1.4 or measurement failure as PAD-positive further enhanced the test parameters. The higher ABI cut-off of 1.0 resulted in somewhat better sensitivities (max 92%) and negative predictive values (max 87%) at the expense of a substantial increase in the number of false positives. Oscillometric method yielded poor sensitivities but very good specificities (max 94%) and positive predictive values (max 90%). Conclusions: Doppler-based LABP provides better results than the guideline-recommended HABP in diabetic patients, nevertheless even this method is not perfect. Increasing the cut-off value to 1.0 in these patients does not bring a substantial improvement of the test performance. Patients with high ABI should be automatically considered PAD-positive and referred for further investigation using imaging techniques.
VytisknoutZobrazeno: 20. 4. 2024 03:58