Detailed Information on Publication Record
2018
Long-term outcomes after treatment of bare-metal stent restenosis with paclitaxel-coated balloon catheters or everolimus-eluting stents: 3-year follow-up of the TIS clinical study
PLEVA, Leos, Pavel KUKLA, Jana ZAPLETALOVA and Ota HLINOMAZBasic information
Original name
Long-term outcomes after treatment of bare-metal stent restenosis with paclitaxel-coated balloon catheters or everolimus-eluting stents: 3-year follow-up of the TIS clinical study
Authors
PLEVA, Leos (203 Czech Republic, guarantor), Pavel KUKLA (203 Czech Republic), Jana ZAPLETALOVA (203 Czech Republic) and Ota HLINOMAZ (203 Czech Republic, belonging to the institution)
Edition
Catheterization and Cardiovascular Interventions, Hoboken, Wiley-Blackwell, 2018, 1522-1946
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
30201 Cardiac and Cardiovascular systems
Country of publisher
United States of America
Confidentiality degree
není předmětem státního či obchodního tajemství
Impact factor
Impact factor: 2.551
RIV identification code
RIV/00216224:14110/18:00105325
Organization unit
Faculty of Medicine
UT WoS
000451188300007
Keywords in English
everolimus-eluting stent; in-stent restenosis; paclitaxel-eluting balloon
Tags
International impact, Reviewed
Změněno: 10/2/2019 15:37, Soňa Böhmová
Abstract
V originále
Background The efficacy of paclitaxel-eluting balloon catheters (PEB) and drug-eluting stents for treatment of bare-metal stent restenosis (BMS-ISR) have been demonstrated in several studies with follow-up times of 9 to 12 months; however, the long-term outcomes of ISR treatment are less defined. Objectives Methods We aimed to compare the long-term efficacy of PEB and everolimus-eluting stents (EES) for the treatment of BMS-ISR. We analyzed 3-year clinical follow-up data from patients included in the TIS randomized clinical study. A total of 136 patients with BMS-ISR were allocated to receive treatment with either PEB or EES (68 patients with 74 ISR lesions per group). Results Conclusions The PEB and EES groups did not significantly differ in major adverse cardiac events-free survival (MACE; P = .211; including individual events: CV death: P = .622; myocardial infarction: P = .650 or target vessel revascularization: P = .286) at 3-year clinical follow-up. No event-free survival differences were found between the groups regarding overall mortality (P = .818), definite stent thrombosis (P = .165) or the second MACE (P = .270). At the 3-year follow-up, no significant differences in clinical outcomes were found between iopromide-coated PEB and EES for the treatment of BMS-ISR. (; ; NCT01735825).