J 2018

Graphene Oxide from Improved Hummers' Method: Is This Material Suitable for Reproducible Electrochemical (Bio)Sensing?

LACINA, Karel, Ondřej KUBESA, Veronika HORÁČKOVÁ, Zdeněk MORAVEC, Jan KUTA et. al.

Základní údaje

Originální název

Graphene Oxide from Improved Hummers' Method: Is This Material Suitable for Reproducible Electrochemical (Bio)Sensing?

Autoři

LACINA, Karel (203 Česká republika, garant, domácí), Ondřej KUBESA (203 Česká republika, domácí), Veronika HORÁČKOVÁ (203 Česká republika, domácí), Zdeněk MORAVEC (203 Česká republika, domácí), Jan KUTA (203 Česká republika, domácí), Vanýsek PETR (203 Česká republika) a Petr SKLÁDAL (203 Česká republika, domácí)

Vydání

ECS Journal of Solid State Science and Technology, 2018, 2162-8769

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10406 Analytical chemistry

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Odkazy

URL

Impakt faktor

Impact factor: 1.795

Kód RIV

RIV/00216224:14740/18:00105948

Organizační jednotka

Středoevropský technologický institut

DOI

http://dx.doi.org/10.1149/2.0171810jss

UT WoS

000446829400001

Klíčová slova anglicky

Graphene; Graphene Oxide; Improved Hummers' Method; Electrochemical (Bio)Sensing

Štítky

CF NANO, rivok
Změněno: 23. 4. 2024 14:53, Mgr. Michal Petr

Anotace

V originále

Graphene as a superior nanomaterial is currently omnipresent and electroanalytical applications are not an exception. In this contribution, its suitability for such applications was critically assessed. We synthesized graphene oxide (GO) in five separate but identical experiments using the improved Hummers' method - well-known and extensively utilized procedure which is typically followed by various operations leading to reduced graphene oxide material. These five repeated trials were precisely controlled to keep the experimental conditions as identical as possible. The resulting five individual GO products were compared by means of elemental analysis, Raman spectroscopy, ICP-MS and AFM. The possible employment of such graphene products - electrochemically reduced GO - for electroanalytical purposes was also probed from the viewpoint of the reproducibility of modification of electrodes and the results seem disconcerting, indicating poor reproducibility. No similar study in reproducibility has been performed until now, since all previous reports always compared only different methods of preparation and only discrete experiments of preparation - repeatability has not been properly addressed.

Návaznosti

CZ.02.1.01/0.0/0.0/16_013/0001761, interní kód MU
Název: RECETOX RI - OP VVV (Akronym: RECETOX RI)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, RECETOX RI - OP VVV, PO 1 Posilování kapacit pro kvalitní výzkum
LM2015043, projekt VaV
Název: Česká infrastruktura pro integrativní strukturní biologii (Akronym: CIISB)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Czech Infrastructure for Integrative Structural Biology
LM2015051, projekt VaV
Název: Centrum pro výzkum toxických látek v prostředí (Akronym: RECETOX RI)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Výzkumná infrastruktura RECETOX
LQ1601, projekt VaV
Název: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
Zobrazeno: 10. 11. 2024 04:14