Informační systém MU
CALUORI, Guido, Jan PŘIBYL, Martin PEŠL, Šárka JELÍNKOVÁ, Vladimír ROTREKL, Petr SKLÁDAL a Roberto RAITERI. Non-invasive electromechanical cell-based biosensors for improved investigation of 3D cardiac models. Biosensors & bioelectronics : the international journal for the professional involved with research, technology and applications of biosensors and related devices. Elsevier Science, 2019, roč. 124, JAN 15 2019, s. 129-135. ISSN 0956-5663. Dostupné z: https://dx.doi.org/10.1016/j.bios.2018.10.021.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Non-invasive electromechanical cell-based biosensors for improved investigation of 3D cardiac models
Autoři CALUORI, Guido (380 Itálie, domácí), Jan PŘIBYL (203 Česká republika, domácí), Martin PEŠL (203 Česká republika, domácí), Šárka JELÍNKOVÁ (203 Česká republika, domácí), Vladimír ROTREKL (203 Česká republika, domácí), Petr SKLÁDAL (203 Česká republika, garant, domácí) a Roberto RAITERI (380 Itálie).
Vydání Biosensors & bioelectronics : the international journal for the professional involved with research, technology and applications of biosensors and related devices, Elsevier Science, 2019, 0956-5663.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30404 Biomaterials
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 10.257
Kód RIV RIV/00216224:14740/19:00107272
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1016/j.bios.2018.10.021
UT WoS 000451935500016
Klíčová slova anglicky Excitation-contraction coupling; Human pluripotent stem cells; Cardiomyocytes; Atomic force microscopy; Microelectrode array; Drug testing
Štítky CF NANO, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 11. 3. 2020 18:00.
Anotace
Cardiomyocytes (CM) placed on microelectrode array (MEA) were simultaneously probed with cantilever from atomic force microscope (AFM) system. This electric,nanomechanical combination in real time recorded beating force of the CMs cluster and the triggering electric events. Such "organ-on-a-chip" represents a tool for drug development and disease modeling. The human pluripotent stem cells included the WT embryonic line CCTL14 and the induced dystrophin deficient line reprogrammed from fibroblasts of a patient affected by Duchenne Muscular Dystrophy (DMD, complete loss of dystrophin expression). Both were differentiated to CMs and employed with the AFM/MEA platform for diseased CMs’ drug response testing and DMD characterization. The dependence of cardiac parameters on extracellular Ca2+ was studied. The differential evaluation explained the observed effects despite variability of biological samples. The beta-adrenergic stimulation (isoproterenol) and antagonist trials (verapamil) addressed ionotropic and chronotropic cell line-dependent features. For the first time, a distinctive beating-force relation for DMD CMs was measured on the 3D cardiac in vitro model.
Návaznosti
GBP302/12/G157, projekt VaVNázev: Dynamika a organizace chromosomů během buněčného cyklu a při diferenciaci v normě a patologii
Investor: Grantová agentura ČR, Dynamika a organizace chromosomů během buněčného cyklu a při diferenciaci v normě a patologii
LM2015043, projekt VaVNázev: Česká infrastruktura pro integrativní strukturní biologii (Akronym: CIISB)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Czech Infrastructure for Integrative Structural Biology
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
MUNI/A/1087/2018, interní kód MUNázev: Molekulární a buněčná biologie pro biomedicínské vědy
Investor: Masarykova univerzita, Molekulární a buněčná biologie pro biomedicínské vědy, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
Zobrazeno: 19. 7. 2024 17:38