DVOŘÁKOVÁ, Magda, Aleš HRDLIČKA, Pavel SLAVÍČEK a Viktor KANICKÝ. MATRIX EFFECTS IN PLASMA PENCIL AND ANALYSIS OF REAL SAMPLES. In 16th Czech - Slovak Spectroscopic Conference. 2018.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název MATRIX EFFECTS IN PLASMA PENCIL AND ANALYSIS OF REAL SAMPLES
Autoři DVOŘÁKOVÁ, Magda (203 Česká republika), Aleš HRDLIČKA (203 Česká republika, garant, domácí), Pavel SLAVÍČEK (203 Česká republika, domácí) a Viktor KANICKÝ (203 Česká republika, domácí).
Vydání 16th Czech - Slovak Spectroscopic Conference, 2018.
Další údaje
Originální jazyk angličtina
Typ výsledku Prezentace na konferencích
Obor 10406 Analytical chemistry
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
WWW odkaz na sborník
Kód RIV RIV/00216224:14740/18:00106686
Organizační jednotka Středoevropský technologický institut
Klíčová slova anglicky plasma; pencil; capacitively coupled; discharge; analytic; atomic; emission; spectroscopy
Štítky rivok
Změnil Změnil: Mgr. Aleš Hrdlička, Ph.D., učo 22863. Změněno: 21. 3. 2019 16:42.
Anotace
Plasma pencil is a capacitively coupled discharge (CCP), which is tested as an alternative excitation source for determination of elements concentrations in solutions [1, 2]. The discharge can excite elements of 1st and 2nd group of the periodic table and also some other metals of which melting and boiling temperatures are not high related to the pencil plasma temperature. Among them mainly copper and zinc emissions were already studied under various conditions. It was shown that intensities of their atomic lines are suppressed by the presence of easily ionisable elements (EIE: 1st and 2nd group of the periodic table) in the sample solution [3]. The suppression was also found in the presence of nitric acid. Significant differences were also found for different anions in combination with sodium cation in the solution. It seems that the most intensive depression effect is caused by chlorides, less effect is observed for nitrates and sulphates and the dependence on the sulphate concentration is not monotonous. To find out if a plasma pencil can be used as an alternative excitation source, we have analyzed real drinking water samples by plasma pencil and ICP-OES and we can say that the yielded results do not differ significantly.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
ED2.1.00/03.0086, projekt VaVNázev: Regionální VaV centrum pro nízkonákladové plazmové a nanotechnologické povrchové úpravy
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
MUNI/A/1288/2017, interní kód MUNázev: Výzkum, vývoj a aplikace v analytické a fyzikální chemii (Akronym: AFCH)
Investor: Masarykova univerzita, Výzkum, vývoj a aplikace v analytické a fyzikální chemii, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
VytisknoutZobrazeno: 25. 4. 2024 03:05