J 2019

An improved design of a passive sampler for polar organic compounds based on diffusion in agarose hydrogel

URÍK, Jakub a Branislav VRANA

Základní údaje

Originální název

An improved design of a passive sampler for polar organic compounds based on diffusion in agarose hydrogel

Vydání

Environmental Science and Pollution Research, Heidelberg, Springer Heidelberg, 2019, 0944-1344

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10511 Environmental sciences

Stát vydavatele

Německo

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 3.056

Kód RIV

RIV/00216224:14310/19:00110397

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000468842100051

EID Scopus

2-s2.0-85064457215

Klíčová slova anglicky

Hydrogel; Passive sampling; Polar organic compounds; Diffusive gradients in thin films (DGT); Water monitoring

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 23. 3. 2020 16:30, Mgr. Marie Novosadová Šípková, DiS.

Anotace

V originále

Passive samplers based on diffusive gradients in thin hydrogel films (DGT) were recently modified for sampling of polar organic compounds in water. However, since the sampling rates of the commonly used DGT design with the surface area of 3.1 cm(2) are low, we propose to increase them by applying a two-sided design with a larger sampling surface area of 22.7 cm(2). The sampler design consists of two sorptive hydrogel disks compressed between two diffusive hydrogel disk layers strengthened by nylon netting and held together by two stainless steel rings. Sorbent/water distribution coefficients (K-SW) were determined, and the sampler was calibrated for monitoring 11 perfluoroalkyl substances and 12 pharmaceuticals and personal care products in water at laboratory conditions using a closed system with artificial flow generated by submersible pumps. A field performance test was conducted at five locations in the Morava River basin in Czech Republic. The median value of laboratory-derived sampling rates was 43 mL day(-1) with extreme values of 2 mL day(-1) and 90 mL day(-1) for perfluorotridecanoic and perfluoroheptanoic acids, respectively. The log K-SW values of tested compounds ranged from 3.18 to 5.47 L kg(-1), and the estimated halftime to attain sampler-water equilibrium ranged from 2 days to more than 28 days, which is the maximum recommended exposure period, considering potential issues with the stability of hydrogel. The sampler can be used for assessment of spatial trends as well as estimation of aqueous concentration of investigated polar compounds.

Návaznosti

EF16_013/0001761, projekt VaV
Název: RECETOX RI
LM2015051, projekt VaV
Název: Centrum pro výzkum toxických látek v prostředí (Akronym: RECETOX RI)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Výzkumná infrastruktura RECETOX
603437, interní kód MU
Název: SOLUTIONS - Solutions for present and future emerging pollutants in land and water resources management (Akronym: SOLUTIONS)
Investor: Evropská unie, SOLUTIONS - Solutions for present and future emerging pollutants in land and water resources management, Spolupráce