Informační systém MU
SCHAUER, Petr, Ondřej LALINSKÝ a Miroslav KUČERA. Prospective scintillation electron detectors for S(T)EM based on garnet film scintillators. Microscopy research and technique. Hoboken: Wiley, 2019, roč. 82, č. 3, s. 272-282. ISSN 1059-910X. Dostupné z: https://dx.doi.org/10.1002/jemt.23169.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Prospective scintillation electron detectors for S(T)EM based on garnet film scintillators
Autoři SCHAUER, Petr, Ondřej LALINSKÝ a Miroslav KUČERA.
Vydání Microscopy research and technique, Hoboken, Wiley, 2019, 1059-910X.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW Full Text
Impakt faktor Impact factor: 2.117
Doi http://dx.doi.org/10.1002/jemt.23169
UT WoS 000459517900012
Klíčová slova anglicky cathodoluminescence; electron detector; LuGAGG:Ce,Mg; multicomponent garnet film; scintillator; SEM; STEM
Štítky RIV ne
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 25. 11. 2019 11:46.
Anotace
The performance of a scintillation electron detector for a scanning electron microscope and/or a scanning transmission electron microscope (S(T)EM) based on new epitaxial garnet film scintillators was explored. The LuGAGG:Ce and LuGAGG:Ce,Mg film scintillators with chemical formula (Ce0.01Lu0.27Gd0.74)(3-w)Mg-w(Ga2.48Al2.46)O-12 were prepared and their cathodoluminescence (CL) and optical properties were studied and compared with the properties of current standard bulk single crystal YAG:Ce and YAP:Ce scintillators. More specifically, CL decay characteristics, CL emission spectra, CL intensities, optical absorption coefficients, and the refractive indices of the mentioned scintillators were measured. Furthermore, electron interaction volumes with absorbed energy distributions, photomultiplier (PMT) photocathode matchings, modulation transfer functions (MTF), and the photon transport efficiencies of scintillation detectors with the mentioned scintillators were calculated. A CL decay time for the LuGAGG:Ce,Mg film scintillator as low as 28 ns with an afterglow of only 0.02% at 1 mu s after the e-beam excitation was observed. As determined from calculated MTFs, the scintillation detectors with the new film scintillators lose contrast transfer ability above 0.6 lp/pixel, while the currently commonly used YAG:Ce single crystal scintillators already do so above 0.1 lp/pixel. It was also calculated that the new studied film scintillators have an 8% higher photon transfer efficiency, even for a simple disk shape compared with the standard bulk single crystal YAG:Ce scintillator. The studied LuGAGG:Ce,Mg epitaxial garnet film scintillators were evaluated as prospective fast scintillators for electron detectors, not only in S(T)EM but also in other e-beam devices.
Zobrazeno: 7. 9. 2024 20:20