Detailed Information on Publication Record
2019
Elusive pKa’ of aminoferrocene determined with voltammetric methods in buffered and unbuffered systems and practical aspects of such experiments
VĚŽNÍK, Jakub, Martin KONHEFR, Libuše TRNKOVÁ, Petr SKLÁDAL, Karel LACINA et. al.Basic information
Original name
Elusive pKa’ of aminoferrocene determined with voltammetric methods in buffered and unbuffered systems and practical aspects of such experiments
Authors
VĚŽNÍK, Jakub (203 Czech Republic, belonging to the institution), Martin KONHEFR (203 Czech Republic, belonging to the institution), Libuše TRNKOVÁ (203 Czech Republic, belonging to the institution), Petr SKLÁDAL (203 Czech Republic, belonging to the institution) and Karel LACINA (203 Czech Republic, guarantor, belonging to the institution)
Edition
Electrochimica Acta, Elsevier, 2019, 0013-4686
Other information
Language
English
Type of outcome
Článek v odborném periodiku
Field of Study
10403 Physical chemistry
Country of publisher
Netherlands
Confidentiality degree
není předmětem státního či obchodního tajemství
References:
Impact factor
Impact factor: 6.215
RIV identification code
RIV/00216224:14310/19:00107678
Organization unit
Faculty of Science
UT WoS
000478969600057
Keywords in English
Ferrocene; Aminoferrocene; Protein labels; pH; Unbuffered solution; Electrochemical determination of pKa’
Tags
Tags
International impact, Reviewed
Změněno: 24/10/2024 12:26, Mgr. Adéla Pešková
Abstract
V originále
Redox behaviour of aminoferrocene (FcNH2) in buffered and unbuffered systems has been studied. In unbuffered solutions with background electrolyte only, two discrete redox pairs of unprotonated and protonated forms were evident. On the other hand, in buffered systems only one redox centre was visible continuously shifting with pH. If one wants to determine the apparent acid dissociation constant pKa’ of ferrocene with protonatable side group, buffered environment will be the first choice. Throughout the electrochemical experiments at such conditions, the most limiting factor was the type of the electrode – gold, platinum, glassy carbon and boron-doped diamond electrodes were probed. We found that the influence of the surface of the electrode was so significant that either the determination of pKa’ was not possible at aqueous conditions or observed differences among the determined values were up to five units. In that case, elusive constants were determined. On the other hand, titrations performed in unbuffered systems appeared to be useable despite inconsistences and deficiencies that can be expected. Determined pKa's agreed well with that quantified using spectrophotometry. Although, experimental work at unbuffered conditions can be considered as incorrect or misleading at the first sight, interesting facts and unexpected mechanisms can be revealed. Especially, when one is aware of the possible risks, and the measurement in different (even unbuffered) media and with different tools are done simultaneously. Finally, a method for estimation of pKa’ of unstable compounds without their separation and isolation was introduced.
Links
GJ19-16273Y, research and development project |
| ||
LQ1601, research and development project |
| ||
MUNI/A/1359/2018, interní kód MU |
| ||
MUNI/A/1575/2018, interní kód MU |
| ||
90043, large research infrastructures |
|