ROHAN, Tomáš, Tomáš ANDRAŠINA, Peter MATKULČÍK, Tomáš JŮZA, Jan ZAVADIL, Iva SVOBODOVÁ, Dalibor ČERVINKA and Vlastimil VÁLEK. Simulation of the biliary metal stent recanalisation using endoluminal irreversible electroporation on porcine liver - in vivo experiment. In CIRSE 2019. 2019. ISSN 1432-086X. Available from: https://dx.doi.org/10.1007/s00270-019-02282-x.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Simulation of the biliary metal stent recanalisation using endoluminal irreversible electroporation on porcine liver - in vivo experiment
Authors ROHAN, Tomáš (203 Czech Republic, guarantor, belonging to the institution), Tomáš ANDRAŠINA (703 Slovakia, belonging to the institution), Peter MATKULČÍK (703 Slovakia, belonging to the institution), Tomáš JŮZA (203 Czech Republic, belonging to the institution), Jan ZAVADIL (203 Czech Republic, belonging to the institution), Iva SVOBODOVÁ (203 Czech Republic, belonging to the institution), Dalibor ČERVINKA (203 Czech Republic) and Vlastimil VÁLEK (203 Czech Republic, belonging to the institution).
Edition CIRSE 2019, 2019.
Other information
Original language English
Type of outcome Conference abstract
Field of Study 30224 Radiology, nuclear medicine and medical imaging
Country of publisher Germany
Confidentiality degree is not subject to a state or trade secret
WWW URL
Impact factor Impact factor: 2.034
RIV identification code RIV/00216224:14110/19:00110835
Organization unit Faculty of Medicine
ISSN 1432-086X
Doi http://dx.doi.org/10.1007/s00270-019-02282-x
Keywords in English biliary intervention; stent recanalisation; irreversible electroporation
Tags rivok
Tags International impact
Changed by Changed by: Mgr. Tereza Miškechová, učo 341652. Changed: 21/4/2020 11:08.
Abstract
Purpose: To demonstrate feasibility of endoluminal irreversible electroporation using tubular catheter in biliary metal stent for recanalisation. Material and methods: 25 simulations of metal stent obstruction on porcine liver in vivo were performed by liver lower edge incision and its insertion in the biliary metal stent. In 14 cases endoluminal irreversible electroporation with tubular catheter prototype were performed, others were set as controls. Three diferent scenarios of IRE were simulated (one, two or zero electrodes in contact with metal stent). Ninety 100 us pulses with 300,650,1000 and 1300 Volts were used in each scenario. Electrical parameters, macroscopical changes, side efects were monitored during the procedure. Early complications were evaluated by CT immediately and 72 hours after the procedure, followed by samples harvesting. Results: There were no complications detected during the procedure and on following CTs, enduluminal IRE was succesful in all cases. Signifcant diference in impedance was observed between all scenario settings (p=0,02, Mann-Whitey). Short circuit occured immediately in 1300 V in all scenarios, in both cases of 1000 V with one electrode in contact with stent and in case where both electrodes were in contact with stent. The highest observed safe voltage for IRE in metal stent was 850 V/cm. Histopathological analysis showed signs of tissue necrosis which were not present in control samples. Conclusion: Endoluminal irreversible electroporation using tubular catheter seems safe and feasible method and has potential for non-thermal metal stent ingrowth treatment.