HODER, Tomáš, Petr SYNEK a Jan VORÁČ. Charge transfer equilibrium in surface barrier discharge: continuous current and negative ion-driven ionisation wave. PLASMA SOURCES SCIENCE and TECHNOLOGY. BRISTOL: IOP PUBLISHING LTD, roč. 28, č. 10, s. 1-12. ISSN 0963-0252. doi:10.1088/1361-6595/ab4b91. 2019.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Charge transfer equilibrium in surface barrier discharge: continuous current and negative ion-driven ionisation wave
Autoři HODER, Tomáš (203 Česká republika, garant, domácí), Petr SYNEK (203 Česká republika, domácí) a Jan VORÁČ (203 Česká republika, domácí).
Vydání PLASMA SOURCES SCIENCE and TECHNOLOGY, BRISTOL, IOP PUBLISHING LTD, 2019, 0963-0252.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10305 Fluids and plasma physics
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.193
Kód RIV RIV/00216224:14310/19:00107807
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1088/1361-6595/ab4b91
UT WoS 000494437100004
Klíčová slova anglicky surface barrier discharge; negative ions; electric current; streamer; electric charge; air; ionisation wave
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 26. 3. 2020 14:06.
Anotace
Sensitive measurements of very weak electrical currents in sinusoidally driven surface barrier discharge in atmospheric air are reported for discharge arrangements with and without liquid covering the top electrode. The transferred charge of the low-power discharge is carefully quantified and it is shown that after the complete voltage period the total charge balance is approaching zero. This rather obvious result is mechanically assumed in the literature, yet it is experimentally not understood in detail. We show that continuous and pulsed micro-ampere currents measured during the negative polarity are responsible for the gradual renewal of the charge transfer equilibrium abruptly distorted by strong electrical pulses caused by positive streamers during the opposite half-period. Using synchronised ICCD imaging we reveal that weak continuous current is caused by slowly expanding surface discharges stemming from previously established cathode spots. The expansion is caused by a surface ionisation wave. Based on the experimental evidence, supported by the theoretical results found in literature, we conclude that an expanding negative ion cloud is responsible for the electric field enhancement at its forefront which is sufficient to ionise the surrounding air.
Návaznosti
GJ16-09721Y, projekt VaVNázev: Pokročilé experimentální studium přechodných povrchových výbojů
Investor: Grantová agentura ČR, Pokročilé experimentální studium přechodných povrchových výbojů
LO1411, projekt VaVNázev: Rozvoj centra pro nízkonákladové plazmové a nanotechnologické povrchové úpravy (Akronym: CEPLANT plus)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Rozvoj centra pro nízkonákladové plazmové a nanotechnologické povrchové úpravy
VytisknoutZobrazeno: 23. 4. 2024 09:05