Other formats:
BibTeX
LaTeX
RIS
@article{1606876, author = {Neuwirth, Radek and Cvek, Jakub and Knybel, Lukas and Jiravský, Otakar and Molenda, Lukas and Kodaj, Michal and Fiala, Martin and Peichl, Petr and Feltl, David and Januska, Jaroslav and Hecko, Jan and Kautzner, Josef}, article_location = {Oxford}, article_number = {7}, doi = {http://dx.doi.org/10.1093/europace/euz133}, keywords = {Ventricular tachycardia; Stereotactic body radiotherapy; Ablation}, language = {eng}, issn = {1099-5129}, journal = {EP Europace}, title = {Stereotactic radiosurgery for ablation of ventricular tachycardia}, url = {http://dx.doi.org/10.1093/europace/euz133}, volume = {21}, year = {2019} }
TY - JOUR ID - 1606876 AU - Neuwirth, Radek - Cvek, Jakub - Knybel, Lukas - Jiravský, Otakar - Molenda, Lukas - Kodaj, Michal - Fiala, Martin - Peichl, Petr - Feltl, David - Januska, Jaroslav - Hecko, Jan - Kautzner, Josef PY - 2019 TI - Stereotactic radiosurgery for ablation of ventricular tachycardia JF - EP Europace VL - 21 IS - 7 SP - 1088-1095 EP - 1088-1095 PB - Oxford University Press SN - 10995129 KW - Ventricular tachycardia KW - Stereotactic body radiotherapy KW - Ablation UR - http://dx.doi.org/10.1093/europace/euz133 L2 - http://dx.doi.org/10.1093/europace/euz133 N2 - Aims Stereotactic body radiotherapy (SBRT) for ventricular tachycardias (VTs) could be an option after failed catheter ablation. In this study, we analysed the long-term efficacy and toxicity of SBRT applied as a bail-out procedure. Methods and results Patients with structural heart disease and unsuccessful catheter ablations for VTs underwent SBRT. The planning target volume (PTV) was accurately delineated using exported 3D electroanatomical maps with the delineated critical part of re-entry circuits. This was defined by detailed electroanatomic mapping and by pacing manoeuvres during the procedure. Using the implantable cardioverter-defibrillator lead as a surrogate contrast marker for respiratory movement compensation, 25 Gy was delivered to the PTV using CyberKnife. We evaluated occurrences of sustained VT, electrical storm, antitachycardia pacing, and shock; time to death; and radiation-induced events. From 2014 until March 2017, 10 patients underwent radiosurgical ablation (mean PTV, 22.15 mL; treatment duration, 68 min). After radiosurgery, four patients experienced nausea and one patient presented gradual progression of mitral regurgitation. During the follow-up (median 28 months), VT burden was reduced by 87.5% compared with baseline (P = 0.012) and three patients suffered non-arrhythmic deaths. After the blanking period, VT recurred in eight of 10 patients. The mean time to first antitachycardia pacing and shock were 6.5 and 21 months, respectively. Conclusion Stereotactic body radiotherapy appears to show long-term safety and effectiveness for VT ablation in structural heart disease inaccessible to catheter ablation. We report one possible radiation-related toxicity and promising overall survival, warranting evaluation in a prospective multicentre clinical trial. ER -
NEUWIRTH, Radek, Jakub CVEK, Lukas KNYBEL, Otakar JIRAVSKÝ, Lukas MOLENDA, Michal KODAJ, Martin FIALA, Petr PEICHL, David FELTL, Jaroslav JANUSKA, Jan HECKO and Josef KAUTZNER. Stereotactic radiosurgery for ablation of ventricular tachycardia. \textit{EP Europace}. Oxford: Oxford University Press, 2019, vol.~21, No~7, p.~1088-1095. ISSN~1099-5129. Available from: https://dx.doi.org/10.1093/europace/euz133.
|