J 2020

Comparison of different methods of thrombus permeability measurement and impact on recanalization in the INTERRSeCT multinational multicenter prospective cohort study

GENSICKE, H., J. W. EVANS, F. S. AL AJLAN, D. DOWLATSHAHI, M. NAJM et. al.

Základní údaje

Originální název

Comparison of different methods of thrombus permeability measurement and impact on recanalization in the INTERRSeCT multinational multicenter prospective cohort study

Autoři

GENSICKE, H. (124 Kanada, garant), J. W. EVANS (124 Kanada), F. S. AL AJLAN (124 Kanada), D. DOWLATSHAHI (124 Kanada), M. NAJM (124 Kanada), A. L. CALLEJA (724 Španělsko), J. PUIG (724 Španělsko), S .L. SOHN (410 Korejská republika), S. H. AHN (410 Korejská republika), A. Y. POPPE (124 Kanada), Robert MIKULÍK (203 Česká republika, domácí), N. ASDAGHI (840 Spojené státy), T. S. FIELD (124 Kanada), A. JIN (124 Kanada), T. ASIL (792 Turecko), J. M. BOULANGER (124 Kanada), M. D. HILL (124 Kanada), M. GOYAL (124 Kanada), A. M. DEMCHUK (124 Kanada) a B. K. MENON (124 Kanada)

Vydání

NEURORADIOLOGY, NEW YORK, SPRINGER, 2020, 0028-3940

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30103 Neurosciences

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Odkazy

URL

Impakt faktor

Impact factor: 2.804

Kód RIV

RIV/00216224:14110/20:00115996

Organizační jednotka

Lékařská fakulta

DOI

http://dx.doi.org/10.1007/s00234-019-02320-y

UT WoS

000495942400003

Klíčová slova anglicky

Acute ischemic stroke; Thrombus permeability; Recanalization therapies; NCCT; CTA

Štítky

14110127, rivok

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 31. 8. 2020 12:13, Mgr. Tereza Miškechová

Anotace

V originále

Purpose To compare the association of different measures of intracranial thrombus permeability on non-contrast computerized tomography (NCCT) and computed tomography angiography (CTA) with recanalization with or without intravenous alteplase. Methods Patients with anterior circulation occlusion from the INTERRSeCT study were included. Thrombus permeability was measured on non-contrast CT and CTA using the following methods: [1] automated method, mean attenuation increase on co-registered thin (< 2.5 mm) CTA/NCCT; [2] semi-automated method, maximum attenuation increase on non-registered CTA/NCCT (Delta HUmax); [3] manual method, maximum attenuation on CTA (HUmax); and [4] visual method, residual flow grade. Primary outcome was recanalization with intravenous alteplase on the revised AOL scale (2b/3). Regression models were compared using C-statistic, Akaike (AIC), and Bayesian information criterion (BIC). Results Four hundred eighty patients were included in this analysis. Statistical models using methods 2, 3, and 4 were similar in their ability to discriminate recanalizers from non-recanalizers (C-statistic 0.667, 0.683, and 0.634, respectively); method 3 had the least information loss (AIC = 483.8; BIC = 492.2). A HUmax >= 89 measured with method 3 provided optimal sensitivity and specificity in discriminating recanalizers from non-recanalizers [recanalization 55.4% (95%CI 46.2-64.6) when HUmax > 89 vs. 16.8% (95%CI 13.0-20.6) when HUmax <= 89]. In sensitivity analyses restricted to patients with co-registered CTA/NCCT (n = 88), methods 1-4 predicted recanalization similarly (C-statistic 0.641, 0.688, 0.640, 0.648, respectively) with Method 2 having the least information loss (AIC 104.8, BIC 109.8). Conclusion Simple methods that measure thrombus permeability are as reliable as complex image processing methods in discriminating recanalizers from non-recanalizers.