PŘIBYL, Jan a Petr SKLÁDAL. Biointerfaces based on immobilized boronic acid with specifity to glycated proteins. In Bastos, T Gamboa, H. BIODEVICES 2008: PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, VOL 2. Setubal: INSTICC-INST SYST TECHNOLOGIES INFORMATION CONTROL & COMMUNICATION. s. 107-112. ISBN 978-989-8111-17-3. 2008.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Biointerfaces based on immobilized boronic acid with specifity to glycated proteins
Autoři PŘIBYL, Jan (203 Česká republika, garant, domácí) a Petr SKLÁDAL (203 Česká republika, domácí).
Vydání Setubal, BIODEVICES 2008: PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, VOL 2, od s. 107-112, 6 s. 2008.
Nakladatel INSTICC-INST SYST TECHNOLOGIES INFORMATION CONTROL & COMMUNICATION
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 20200 2.2 Electrical engineering, Electronic engineering, Information engineering
Stát vydavatele Portugalsko
Utajení není předmětem státního či obchodního tajemství
Forma vydání tištěná verze "print"
Organizační jednotka Přírodovědecká fakulta
ISBN 978-989-8111-17-3
UT WoS 000256526900021
Klíčová slova anglicky glycated hemoglobin; aminophenylboronic acid; biosensors; quartz crystal microbalance; heterogeneous affinity assay; microtitre plate
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 20. 8. 2020 14:26.
Anotace
Development of bioanalytical assays for determination of glycated hemoglobin content in blood samples is reported. First, a combined biosensor setup for determination of total and glycated hemoglobin content was successfully developed and tested. The effect of various operating parameters, such as ionic strength, flow rate and instrumental set-up was optimized. The total hemoglobin content was analyzed by measuring of absorbance of the hemoglobin-cyanide derivative at 540 nm. Only one standard (calibrator), diluted in various proportions, was necessary for the method calibration. The full range of HbA(1c) content (4 to 15 %) presented in blood can be analyzed. Only 1 mu l of blood was required for analysis. The developed method was successfully evaluated for analysis of blood samples collected from diabetic patients. Next, the heterogeneous affinity assay performed in a microtitre plate with an immobilized boronic acid is described. This assay is based on ELISA (Enzyme-Linked Immunosorbent Assay) principle; however stable chemiselective ligand is used in this case. The content of glycated hemoglobin is determined according to its peroxidase activity after attachment to immobilized boronic acid derivative; the total hemoglobin concentration is measured as an absorbance at 405 nm.
VytisknoutZobrazeno: 20. 4. 2024 00:51