ĎURČ, Pavol, František FORET, Lukáš HOMOLA, Miriam MALÁ, Eva POKOJOVÁ, Hana VINOHRADSKÁ, Milan DASTYCH, Dagmar KRAUSOVÁ, D. NAGY, O. BEDE, P. DREVINEK, V. SKALICKA and Petr KUBÁŇ. Skin wipe test: A simple, inexpensive, and fast approach in the diagnosis of cystic fibrosis. Pediatric Pulmonology. 111 RIVER ST, HOBOKEN 07030-5774,: WILEY, 2020, vol. 55, No 7, p. 1653-1660. ISSN 8755-6863. Available from: https://dx.doi.org/10.1002/ppul.24758. |
Other formats:
BibTeX
LaTeX
RIS
@article{1677134, author = {Ďurč, Pavol and Foret, František and Homola, Lukáš and Malá, Miriam and Pokojová, Eva and Vinohradská, Hana and Dastych, Milan and Krausová, Dagmar and Nagy, D. and Bede, O. and Drevinek, P. and Skalicka, V. and Kubáň, Petr}, article_location = {111 RIVER ST, HOBOKEN 07030-5774,}, article_number = {7}, doi = {http://dx.doi.org/10.1002/ppul.24758}, keywords = {capillary electrophoresis; cystic fibrosis; diagnosis; ion ratio; screening; skin wipe test; sweat test}, language = {eng}, issn = {8755-6863}, journal = {Pediatric Pulmonology}, title = {Skin wipe test: A simple, inexpensive, and fast approach in the diagnosis of cystic fibrosis}, url = {https://onlinelibrary.wiley.com/doi/full/10.1002/ppul.24758}, volume = {55}, year = {2020} }
TY - JOUR ID - 1677134 AU - Ďurč, Pavol - Foret, František - Homola, Lukáš - Malá, Miriam - Pokojová, Eva - Vinohradská, Hana - Dastych, Milan - Krausová, Dagmar - Nagy, D. - Bede, O. - Drevinek, P. - Skalicka, V. - Kubáň, Petr PY - 2020 TI - Skin wipe test: A simple, inexpensive, and fast approach in the diagnosis of cystic fibrosis JF - Pediatric Pulmonology VL - 55 IS - 7 SP - 1653-1660 EP - 1653-1660 PB - WILEY SN - 87556863 KW - capillary electrophoresis KW - cystic fibrosis KW - diagnosis KW - ion ratio KW - screening KW - skin wipe test KW - sweat test UR - https://onlinelibrary.wiley.com/doi/full/10.1002/ppul.24758 L2 - https://onlinelibrary.wiley.com/doi/full/10.1002/ppul.24758 N2 - Objective To assess the performance of a newly developed skin wipe test (SWT) for the diagnosis of cystic fibrosis (CF). Study Design Spontaneously formed sweat from the forearm was wiped by a cotton swab moistened with 100 mu L of deionized (DI) water and extracted into 400 mu L of DI water (SWT). The conventional Macroduct sweat test (ST) was performed simultaneously. SWT samples of 114 CF patients, 76 healthy carriers, and 58 controls were analyzed by capillary electrophoresis with contactless conductivity detection and Cl-/K(+)and (Cl- + Na+)/K(+)ion ratios were evaluated. Chloride concentrations from Macroduct ST were analyzed coulometrically. Results Analysis of 248 SWT samples and simultaneous Macroduct ST samples showed comparable method performance. Two ion ratios, Cl-/K(+)and (Cl- + Na+)/K+, from the SWT samples and Cl(-)values from the ST samples were evaluated to diagnose CF. Sensitivity of the SWT method using the Cl-/K(+)ratio (cutoff value 3.9) was 93.9%, compared to 99.1% when using the (Cl- + Na+)/K(+)ratio (cutoff value 5.0) and 98.3% in using Macroduct Cl-(cutoff value higher or equal to 60 mmol/L). The methods' specificities were 97.8%, 94.0%, and 100.0%, respectively. Conclusions The developed SWT method with capillary electrophoretic analysis for CF diagnosis performs comparably to the conventional Macroduct ST. The SWT method is simple, fast, inexpensive, and completely noninvasive. Use of an ion ratio in obtained SWT samples is proposed as a new diagnostic parameter that shows significant promise in CF diagnostics. ER -
ĎURČ, Pavol, František FORET, Lukáš HOMOLA, Miriam MALÁ, Eva POKOJOVÁ, Hana VINOHRADSKÁ, Milan DASTYCH, Dagmar KRAUSOVÁ, D. NAGY, O. BEDE, P. DREVINEK, V. SKALICKA and Petr KUBÁŇ. Skin wipe test: A simple, inexpensive, and fast approach in the diagnosis of cystic fibrosis. \textit{Pediatric Pulmonology}. 111 RIVER ST, HOBOKEN 07030-5774,: WILEY, 2020, vol.~55, No~7, p.~1653-1660. ISSN~8755-6863. Available from: https://dx.doi.org/10.1002/ppul.24758.
|