Další formáty:
BibTeX
LaTeX
RIS
@article{1692697, author = {Pitschmann, Vladimír and Matějovský, Lukáš and Zeman, Jiří and Vetchý, David and Dymák, Michal and Lobotka, Martin and Pavloková, Sylvie and Moravec, Zdeněk}, article_number = {4}, doi = {http://dx.doi.org/10.3390/chemosensors8040107}, keywords = {detection tubes; chemosensor; visual and fluorescence detection; phosgene; composite pellets}, language = {eng}, issn = {2227-9040}, journal = {Chemosensors}, title = {Second-Generation Phosgene and Diphosgene Detection Tube}, url = {http://www.mdpi.com/2227-9040/8/4/107/htm}, volume = {8}, year = {2020} }
TY - JOUR ID - 1692697 AU - Pitschmann, Vladimír - Matějovský, Lukáš - Zeman, Jiří - Vetchý, David - Dymák, Michal - Lobotka, Martin - Pavloková, Sylvie - Moravec, Zdeněk PY - 2020 TI - Second-Generation Phosgene and Diphosgene Detection Tube JF - Chemosensors VL - 8 IS - 4 SP - 1-10 EP - 1-10 PB - MDPI AG SN - 22279040 KW - detection tubes KW - chemosensor KW - visual and fluorescence detection KW - phosgene KW - composite pellets UR - http://www.mdpi.com/2227-9040/8/4/107/htm L2 - http://www.mdpi.com/2227-9040/8/4/107/htm N2 - We have developed a second-generation detection tube for colorimetric and fluorescence detection of phosgene and diphosgene in air. The tube is packed with pellets made of a mixture of microcrystalline cellulose and magnesium aluminum metasilicate treated with a suitable monoterpene (camphor, menthol) to increase porosity and specific surface area. We impregnated the pellets with a specific o-phenylenediamine-pyronin (PY-OPD) based reagent. The detector with this novel indication charge enables phosgene or diphosgene to be selectively and sensitively detected at concentrations lower than as would those posing acute health risk. Owing to the analytical colorimetric and, at the same time, fluorescence signal, the detector is very robust while featuring good sensitivity and variability. The colorimetric limits of detection were 0.3 mg/m3 (tristimulus colorimeter), resp. 5 mg/m3 (with the naked eye), fluorescence detection limits of 0.3 mg/m3 (with the naked eye), all at an air sample volume of 1 dm3. The response was practically immediate, acid vapors and gases, or diethyl chlorophosphate as a simulant of nerve warfare chemical agents, were disruptive. ER -
PITSCHMANN, Vladimír, Lukáš MATĚJOVSKÝ, Jiří ZEMAN, David VETCHÝ, Michal DYMÁK, Martin LOBOTKA, Sylvie PAVLOKOVÁ a Zdeněk MORAVEC. Second-Generation Phosgene and Diphosgene Detection Tube. \textit{Chemosensors}. MDPI AG, 2020, roč.~8, č.~4, s.~1-10. ISSN~2227-9040. doi:10.3390/chemosensors8040107.
|